Operation – Hot Max Torches WP30TP User Manual
Page 10
KDAR Company
9
Operation
Shutting Down the Pump
Note: For emergency engine stop, simply turn
the engine switch to OFF.
1. Move the throttle lever to the SLOW position.
2. Turn the engine switch to the OFF position.
3. Turn fuel valve to the off position.
Note: When the pump is not in use the fuel
valve should be in the OFF position.
4. Remove the pump drain plug and drain the
pump chamber.
5. Remove filler cap from the pump and flush
the pump chamber with clean water.
6. Allow water to drain from the pump chamber
and replace filler cap and drain plug.
SLOW
Filler
Cap
Drain
Plug
Cleaning the Pump Housing
NOTE: It is very impor tant that the pump
housing is opened and cleaned after every use to
insure debris does not harden and damage the
pump during the next start up.
1. Loosen T-Bolts and remove pump cover.
These bolts are very tight and may need to be
loosened with tool for leverage.
NOTE: The T-Bolts have retaining o-rings to
hold them in place, pulling them out will dam-
age the o-ring.
T-Bolts
T-Bolts