beautypg.com

Operation – Hot Max Torches WP30TP User Manual

Page 10

background image

KDAR Company

9

Operation

Shutting Down the Pump

Note: For emergency engine stop, simply turn
the engine switch to OFF.


1. Move the throttle lever to the SLOW position.

2. Turn the engine switch to the OFF position.

3. Turn fuel valve to the off position.

Note: When the pump is not in use the fuel
valve should be in the OFF position.

4. Remove the pump drain plug and drain the

pump chamber.

5. Remove filler cap from the pump and flush

the pump chamber with clean water.

6. Allow water to drain from the pump chamber

and replace filler cap and drain plug.

SLOW

Filler
Cap

Drain
Plug

Cleaning the Pump Housing

NOTE: It is very impor tant that the pump
housing is opened and cleaned after every use to
insure debris does not harden and damage the
pump during the next start up.

1. Loosen T-Bolts and remove pump cover.

These bolts are very tight and may need to be
loosened with tool for leverage.

NOTE: The T-Bolts have retaining o-rings to
hold them in place, pulling them out will dam-
age the o-ring.

T-Bolts

T-Bolts