Electrix Framing System User Manual
Electrix Lighting

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING
RECOMMENDED COVE HEIGHT
In order to achieve optimal lighting results, the following cove to
ceiling dimensions are recommended. However, please refer to
detailed plans as architect specifications take precedence.
Double Lamp - Parallel
T5
- 18”
T5 HO
- 24”
T8
- 12”
Single Lamp - Tandem
T5
- 12”
T5 HO
- 18”
T8
- 10”
2” x 4” SWITCHBOX
(MOUNTED HORIZONTALLY)
1. Coordinate the location of a 2” x 4” switchbox
mounted horizontally with electrician. Snap
or laser HORIZONTAL guideline. Align the
bottom of the wall extrusion with the
switchbox. (Figure A).
2” x 4” SWITCHBOX
(MOUNTED HORIZONTALLY)
A
WALL EXTRUSION
B
2. Mount the first Wall Extrusion and fasten to
ALL vertical wall studs. (Figure B).
P/N 3249