beautypg.com

Caution – Kestrel 3500 Delta T User Manual

Page 5

background image

9

8

MAINTENANCE & SERVICE

Replacing the Battery
When your display becomes dim or disappears, you need to

change the battery.
Use a US nickel or similar coin to twist open the battery

compartment.
Replace battery with a new, clean CR2032 coin-cell battery,

with positive side (+) facing up.
CR2032 batteries are available in most stores that sell

batteries.

When replacing the battery door, be sure to keep the black rubber o-ring

seated in the groove on the case back.

Hold Mode

Hold Mode can be useful for taking measurements when you are

unable to view the display.

• Hold down , then press

.

• The word “HOLD” will blink on each screen and all values

will stop measuring and freeze in memory.

• Use

or

to view each Measurement screen in Hold

Mode.

• To exit Hold Mode, hold down , then press

again.

Backlight*
• Press to activate the backlight for 10 seconds.

• Press again to manually deactivate the backlight

before 10 seconds expire.

*The Kestrel 1000 Meter does NOT offer a backlight.

MEASUREMENT NOTES

MEASUREMENTS

Barometric Pressure Trend

: indicates pressure is rising quickly (> +0.18 inHg) in 3 hours
: indicates pressure is rising (within +0.06 and +0.18 inHg)
: indicates pressure is stable (remains between -0.06 and +0.06 inHg)
: indicates pressure is dropping (within -0.06 and -0.18 inHg)
: indicates pressure is falling quickly (> -0.18 inHg)

Select Units of Measure
• Use

or

to scroll to the desired Measurement

screen.

• Hold down , then press

to set the desired Units of

Measure for the Measurement.

Water and Snow Temperature
The Kestrel Meter may also be used to measure the

temperature of water and snow. Submerge the thermistor

portion (curly exposed wire in window next to

impeller) in water or snow to get an accurate reading.

Kestrel Meters are completely waterproof, float and can be

safely submerged in water according to IP-67 standards

(up to 1 meter for a maximum of 30 minutes).
Max/Avg Function
To view the maximum wind gust recorded, press

or

until you see “MAX” appear at bottom of screen. Press

again to view average wind gust. “AVG” will appear at

bottom of screen. Both Max and Average are reset each

time the unit is powered down. To restart averaging,

simply turn the unit off and back on again.

MAINTENANCE & SERVICE

CAUTION

!

CR2032 batteries contain lithium, a toxic substance. Ingestion may cause serious injury or death. Keep battery

out of the reach of children. If swallowed, immediately seek medical help. Have doctor phone 24-hour hotline

at (202) 625-3333, call collect if necessary. Dispose of batteries properly and according to local regulations. Do

not puncture or burn batteries.

This manual is related to the following products: