GETTING STARTED
Turning ON and OFF
• Press to turn on.
• Hold for 3 seconds to turn off.
The Kestrel Meter will automatically turn off if no buttons have been
pressed for 45 minutes.
Select Measurement Mode
• Use
or
to access each Measurement screen
• The instantaneous Measurement value will be displayed
on each screen and updated once per second.
Each Measurement screen will flash a brief “Hint” to clarify which
Measurement is being displayed. Note: Hints are not displayed in the
Kestrel 1000.
The Measurement’s icons and units of measure will be displayed in the
lower line of the screen.
BAROMETRIC PRESSURE & ALTITUDE ADJUSTMENT
75.2
°F
°F
Temperature “Hint”
flashes before
Temperature
Measurement Screen
SETTING REFERENCE BAROMETRIC PRESSURE &
ALTITUDE: KESTREL 2500 & KESTREL 3500 ONLY
The Kestrel Meter measures “station pressure,” which changes in
response to both changes in altitude and changes in atmosphere.
Barometric pressure is a measurement of the air pressure adjusted to
sea level. To obtain accurate barometric pressure and altitude
readings, you must first enter EITHER your location’s current
barometric pressure OR your current altitude.
*Station pressure is displayed if the reference altitude is set to zero.
Starting with Known Altitude for your Location
• Use
or
to highlight the “BARO” screen.
• Press
and
simultaneously until the word “REF”
starts blinking on screen.
• Use
or
to adjust the value to the correct known
Altitude.
• Press
and
simultaneously to exit the reference
setting mode.
After the Altitude reference is set, place the unit on a table and allow
it to stabilize. The accurate Barometric Pressure reading will then be
displayed on screen.
Note the correct barometric pressure reading
above and use this measurement to set the
Altitude:
• Use
or
to highlight the “Altitude” screen.
• Press
and
simultaneously until the word “REF”
starts blinking on screen.
• Use
or
to adjust the value to the barometric
pressure measurement noted above.
• Press
and
simultaneously again to exit the
setting mode.
Starting with Known Barometric Pressure for your
Location
• Use
or
to highlight the “Altitude” screen.
• Press
and
simultaneously until the word “REF” starts
blinking on screen.
• Use
or
to adjust the reference value to the correct
known Barometric Pressure.
• Press
and
simultaneously again to exit the setting
mode.
After the Pressure reference is set, place the unit on a table and allow
it to stabilize. The accurate Altitude reading will then be displayed
on screen.
Note the correct altitude reading above and use this to
set the Barometric Pressure:
• Use
or
to highlight the “BARO” screen.
• Press
and
simultaneously until the word “REF” starts
blinking on screen.
• Use
or
to adjust the reference value to the correct
known Altitude.
• Press
and
simultaneously again to exit the
setting mode.
Once these steps are complete, both screens will display
accurate readings.
*Be sure to adjust your reference measurements when you change your
location for altitude and/or barometric pressure or when there has been
dramatic change in weather conditions.
SETUP + OPTIONS
Select the Unit of Measure
• Select the unit of measure. While holding , press
to scroll through the available units of measure for that
measurement.
Adjust the Clock
*This applies to the 2500, 2500NV, 3500, 3500NV and 3500DT.
• Adjust the clock. Simultaneously press
and
to access clock setting. While the time is blinking,
press
or
to change the time. Hold either
button down to adjust quickly. Simultaneously
press
and
to exit clock setting.