Ema linear actuator, Electrical installation 7.1 – Power Jacks EMA Actuators User Manual
Page 12
![background image](/manuals/408797/12/background.png)
EMA Linear Actuator
Tel: +44 (0) 1358 285100 email: [email protected]
web: www.powerjacks.com
12
7.
Electrical Installation
7.1
Limit Switch
– Electro-Mechanical Type
Item
Description
Housing
Metal, compact housing, totally
enclosed and sealed.
Pre-Cabled
2m PVC cable 5x0.75mm
2
(other
cable
lengths
available
on
request).
Switch type
Single-pole, 1 change-over, snap
action.
Switch Actuation
End of plunger (metal).
Max actuation speed
0.5 m/s
Mechanical durability
10 million operating cycles.
Ambient temperature
Operation
Storage
-25°C +70°C
-40°C +70°C
Product conformity
IEC947-5-1
Enclosure
IP67
Operating characteristics AC-15; B300 (Ue=240V, Ie=1.5A)
DC-13; R300 (Ue=250V, Ie=0.1A)
Insulation voltage
Ui=300V
7.2
Mounting the drive motor
The electrical installations and the checking of the direction of rotation
may only be carried out be a licensed electrician.
Connect the motor in compliance with the electro-technical regulation
Before mounting the motor, check the direction of rotation / linear travel of the EMA
actuator and the operation of the limit switches (if fitted). In order to do this:
1. Place the motor at the mounting position near the gearbox input.
2. Switch on the motor and check the direction of rotation.
3. Check the direction of rotation / linear travel by manually turning the gearbox input
shaft. Change the direction of the motor rotation if necessary by changing motor
connections.
4. Where necessary, attach coupling halves to motor shaft.
5. Mount motor onto gearbox input flange using screws provided.