This chapter provides technical data of WAC151 Cross
Arm.
Specifications
Table 4
WAC151 Cross Arm Specifications
Property
Description / Value
I/O connectors
Screw terminal connectors (15 pcs) for
the sensors and power lines.
Cable entries
Signal cable
Sensor cables
Totally four
Through a gland (for cable diameter
7 ... 10mm) with coaxial connectability
of the cable screen, for proper RF
shielding.
Through two rubber glands.
Thermostat switch
Connects at +4 °C (
±3 °C)
Disconnects at +11 °C (
±3 °C)
Mounting
Clamp for a pole mast with a nominal
outside diameter 60 mm.
Material
Cross Arm
Junction Box
Al, anodized
Al, painted
Dimensions
Cross Arm length
Junction Box
800 mm
125 x 80 x 57 mm
Weight
1.5 kg (without sensors)