TECHNICAL DATA
Property Description
/
Value
Materials
Plates
Polycarbonate
Bars
Offshore Aluminium
Mounting
with 2 bolts
(M6 x minimum 20 mm)
Weight
800 g
Hose connection
barbed fitting for 4 mm I.D.
hose or Rp1/4 thread
(parallel)
WARRANTY
Visit our Internet pages for standard warranty terms and
conditions:
Please observe that any such warranty may not be valid in case
of damage due to normal wear and tear, exceptional operating
conditions, negligent handling or installation, or unauthorized
modifications. Please see the applicable supply contract or
Conditions of Sale for details of the warranty for each product.
TECHNICAL SUPPORT AND PRODUCT
RETURNS
For technical questions, contact the Vaisala technical support by
e-mail at
If the product must be returned for service, see
.
For contact information of Vaisala Service Centers, see
MAINTENANCE
Figure 3 Detaching the Lower Plate for Cleaning
Cleaning the SPH10 is done by detaching the lower bar and the
lower plate. The barometer can be in place while cleaning the
plates. Follow the instructions below:
1. Unscrew the lower bar and detach it.
2. Open the self-locking nut with a 13 mm spanner.
3. Remove the threaded sleeve and take out the lower plate
and the protective wire net.
4. Clean the plates.
5. Replace the lower plate, the protective wire net and the
threaded sleeve, screw back the nut and the lower bar.
Keep the holes of the lower plate open to allow the water run
out.
DIMENSIONS
All dimensions in mm.