beautypg.com

Installation procedure – Haws 8100 User Manual

Page 2

background image

12/09

Model 8100

Page 2 of 5


LOCATION OF UNIT: The Model 8100 Emergency Shower should be installed in close
proximity to potential accident areas. It should be clearly identified, free from obstructions
and easy to access.

SUPPLY LINE: The minimum recommended line size is 1-1/4” NPT with 30-90 psi (2-6
ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.

PLUMBING CONNECTIONS: Inlet supply connection is female 1-1/4” NPT.

INSTALLATION PROCEDURE

Refer to Installation Drawing for clarification. Check parts list to insure all required parts are
included. Use pipe joint sealant PST #565 (Loctite) on all connections.

STEP 1: Prepare the emergency shower foundation by using the floor flange assembly as

a template. Locate the three holes for the 3/8-16 UNC x 6” anchor bolts (not
supplied). They should extend 1” above the floor level.

STEP 2: Once the concrete foundation is ready (dry), assemble the floor flange assembly

to the anchor bolts; then securely fasten with 3/8-16 UNC Hex Nuts and 3/8”
washers (not supplied). Seal and tighten floor flange and coupling making certain
the foot control holes are facing side to side.

STEP 3: Assemble nipple (1-1/4” x 33”) to the floor flange assembly and tighten with a pipe

wrench.

STEP 4: Assemble in the following order:

Attach intermediate coupling to nipple (1-1/4” x 33”)

Attach plugged nipple (1-1/4” x 24”) and tee (1-1/4”) onto the coupling.

Attach nipple (1-1/4” x 24”) onto the tee.

Attach tee (1-1/4” x 1-1/4” x 1”) onto nipple.

Attach nipple (1” x 9”) valve assembly onto tee (1-1/4” x 1-1/4” x 1”)

Assemble the street elbow (1”) onto nipple (1” x 12-1/2”).

Attach nipple onto valve.

STEP 5: Attach the showerhead onto street elbow (1”).

STEP 6: Assemble the sign onto the unit. Use the strap, screws, washers and nuts

provided to mount the sign onto the upright. The sign should be positioned for
maximum visibility

STEP 7: Insert the galvanized plug into the optional supply line tee that is not used. Before

connecting the supply water line to the emergency shower, FLUSH THE LINE
THOROUGHLY.