TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1. No flow.
1.
Check the main shut-off valve.
2. Insufficient
water flow, shower and
eyewash.
2.
Verify minimum 30 psi (2 ATM) 
flowing supply line pressure. 
3. Insufficient water flow on eye/face
wash, however, shower is 
sufficient. 
3. a. Verify minimum 30 psi (2 ATM)
flowing supply line pressure.
b. Probable clogging of flow control
due to inadequate line flushing. 
Unscrew eye/face wash head and 
remove the four screws to 
disassemble the head. Clean flow 
control and reassemble head. See 
SP65 Installation Drawing for 
details. 
4. Eye/face wash stream does not
meet desired eye level.
4. a. Possible blocked flow control, see
above solution.
b. Possible non-leveled eye/face wash
assembly.
5. Insufficient water flow at the
showerhead, however, eye/face 
wash is sufficient. 
5.
Probable clogging of flow control 
inside shower head. Unscrew 
shower head off of elbow and clean 
rubber flow control. 
6. Water does not drain properly.
6.
Check your drain system for debris. 
Check the main waste line of your 
building to see if it does handle the 
capacity required for the entire 
drainage system. 
7. Water leak between joints or
fittings.
7.
Tighten loose connections. If leak 
persists, the application of hot water 
will sometimes reseat improperly 
applied joint compound. After 30 
minutes wait and retest, a persistent 
leak will necessitate reassembly and 
additional sealant. 
 
 
For more information on Haws Products, please see our website:
www.hawsco.com
© 2012 Haws
®
Corporation – All Rights Reserved
HAWS
®
and other trademarks used