19

water heater installation

t&p ValVe discharge pipe

Explosion Hazard

Temperature-Pressure Relief Valve

must comply with ANSI Z21.22-

CSA 4.4 and ASME code.

Properly sized temperature-

pressure relief valve must be

installed in opening provided.
Can result in overheating and

excessive tank pressure.
Can cause serious injury or death.

This water heater is provided with a properly rated/sized and

certified combination temperature - pressure (T&P) relief valve by

the manufacturer. See Temperature-Pressure relief Valve on pages

13-14 for information on replacement and other requirements.

Water Damage Hazard

Temperature-Pressure Relief Valve discharge

pipe must terminate at adequate drain.

CAUTION

Install a discharge pipe between the T&P valve discharge opening and

a suitable floor drain. Do not connect discharge piping directly to the

drain unless a 6” (15.2 cm) air gap is provided. To prevent bodily injury,

hazard to life, or property damage, the relief valve must be allowed

to discharge water in adequate quantities should circumstances

demand. If the discharge pipe is not connected to a drain or other

suitable means, the water flow may cause property damage.
t&p Valve discharge pipe requirements:

• Shall not be smaller in size than the outlet pipe size of the

valve, or have any reducing couplings or other restrictions.

• Shall not be plugged or blocked.
• Shall not be exposed to freezing temperatures.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both the

Temperature-Pressure relief Valve and the discharge pipe.

• Must terminate a maximum of six inches above a floor drain

or external to the building. In cold climates, it is recommended

that the discharge pipe be terminated at an adequate drain

inside the building.

• Shall not have any valve or other obstruction between the

relief valve and the drain.

The type, size and location of the relief valves must be in

accordance with local codes. The locations of the relief valves

shown in the installation diagrams are typical. See pages 34-48.

The heater has a factory installed high temperature limit switch

and temperature and pressure relief valve.
Cold water lines to heater should be installed as shown in order to

minimize gravity circulation of hot water to building cold water lines.
A listed temperature and pressure relief valve of adequate capacity

is installed on the heater. The locations shown in the installation

diagrams on pages 34-48 are typical.
The discharge opening of the temperature and pressure relief

valve must be piped to an open drain and should not be subject

to freezing temperatures.
Install in accordance with all local codes.

water line connections

The water piping installation must conform to these instructions

and to all local code authority having jurisdiction. Good practice

requires that all heavy piping be supported.
read and observe all requirements in the following sections

before installation of the water piping begins:
1. Water Temperature Control and Mixing Valves on page 12.
2. Dishwashing Machines on page 13.
3. Closed Systems and Thermal expansion on page 13.
4. Temperature-Pressure relief Valve on page 13.
5. For multiple water heater installations see Water Piping

Diagrams beginning on page 34.

This manual provides detailed installation diagrams (see pages

34-48 of this manual) for typical methods of application for the

water heater(s).
water (potaBle) heating and space heating
1. All piping components connected to this unit for space heating

applications shall be suitable for use with potable water.

2. Toxic chemicals, such as those used for boiler treatment, shall

NeVer be introduced into this system.

3. This unit may NeVer be connected to any existing heating

system or component(s) previously used with a non-potable

water heating appliance.

4. When the system requires water for space heating at

temperatures higher than required for domestic water

purposes, a tempering valve must be installed. Please refer

to installation diagrams on pages 34-48 of this manual for

suggested piping arrangements.

5. These water heaters cannot be used in space heating

applications only.

thermometers (not supplied)

Thermometers should be obtained and field installed as shown in

the installation diagrams.
Thermometers are installed in the system as a means of detecting

the temperature of the outlet water supply.

water piping diagrams

This manual provides detailed water piping diagrams for

typical methods of application for the water heaters, see

Water Piping Diagrams beginning on page 34. The water

heater may be installed by itself, or with a separate storage

tank, on both single and two-temperature systems. When

used with a separate storage tank, the circulation may

be either by gravity or by means of a circulating pump.

Adjust flow by throttling a full port ball valve installed in the

circulating line on the outlet side of the pump. Never throttle

flow on the suction side of a pump. See the Water Piping

Diagrams beginning on page 34.
note: In addition to the factory installed Temperature-

Pressure relief Valve (T&P valve) on the water heater, each

remote storage tank that may be installed and piped to a

water heating appliance must also have its own properly

sized, rated and approved Temperature-Pressure relief

Valve installed. Call the toll free technical support phone

number listed on the back cover of this manual for further

assistance in sizing a T&P valve for remote storage tanks.