Periodic Maintenance (cont’d)

16. Replace terminal cover on thermostat making sure the

locking tabs on the terminal cover are in place.

17. Replace the insulation block so that it covers the ther-

mostat and element.

18. Replace access panel.

19. Turn “ON” electric power to water heater.

Element Cleaning/

Replacement (cont’d)

18

Drain Valve Washer

Replacement (Note: only 30

gallon model is equipped with

drain valve.)

NOTE: For replacement, use a

17

32

″″ x

13

64

″″ x

1

8

″″ thick

washer available at your nearest hardware store.

1. Before beginning turn “OFF” the electrical power sup-

ply to the water heater.

2. Follow “Draining” instructions. See “Draining” instruc-

tions in the “Periodic Maintenance” section.

3. Turning counter clockwise, remove the hex cap below

the screw handle.

4. Remove the washer and put the new one in place.

5. Screw the handle and cap assembly back into the drain

valve and retighten using a wrench. DO NOT OVER

TIGHTEN.

6. Follow “Filling the Water Heater” instructions in the

“Installing the New Water Heater” section.

7. Check for leaks.

8. Turn “ON” electric power to the water heater.

Service

If a condition persists or you are uncertain about the oper-

ation of the water heater, let a qualified person check it

out. Call a local plumbing contractor or qualified service-

man, the local electric utility, or the local water utility.

WASHER

HANDLE AND

CAP ASSEMBLY

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any

access panels or servicing the water heater, make sure the

electrical supply to the water heater is turned “OFF”.

Failure to do this could result in DEATH, SERIOUS BODI-

LY INJURY, OR PROPERTY DAMAGE.

This manual is related to the following products: