Periodic Maintenance (cont‘d)

Thermostat Removal

1. Turn “OFF” the electrical power to the water heater at the

junction box.

4. Remove the two wires attached to the thermostat.
5. Remove the thermostat from behind the thermostat bracket.
6. Disconnect wires from thermostat and slide out of the

bracket.

7. Place the new lower thermostat in the bracket making

sure it fits firmly against the tank.

8. Attach the wires to the new thermostat.

NOTE: Some of the terminals may require straight-in

wiring through an eye-opening. If wires are now looped,

re-cut and strip wire

3

8

to a straight length and insert.

9. Put plastic terminal cover back in place.

10. Carefully replace insulation block to cover the thermo-

stat and element.

11. Replace access panel, then turn the electric power on.

B. Models with Upper or Lower Thermostat with High

Limit: Lift out the tab as shown below to unclip the termi-

nal cover from the thermostat. The terminal cover can

now be removed from the thermostat.

THERMOSTAT BRACKET

TERMINAL COVER CLIPPED TO

THERMOSTAT AT THIS POINT

PLASTIC TABS ON

BOTH SIDES OF

TERMINAL COVER

HOLD IT IN PLACE.

TANK

ELEMENT

LOWER THERMOSTAT

JACKET

JACKET

Lift out tab to unclip

terminal cover from

thermostat.

Lift out tab to unclip

terminal cover from

thermostat.

2. Remove the access panel and remove the insulation block.

3. A. Models with Lower Thermostat without high limit: Lift

out the tab as shown to unclip the terminal cover from

the thermostat. The terminal cover can now be removed

from the thermostat.

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any

access panels or servicing the water heater, make sure the

electrical supply to the water heater is turned “OFF”.

Failure to do this could result in DEATH, SERIOUS BODI-

LY INJURY, OR PROPERTY DAMAGE.