beautypg.com

Installation considerations – State GPH-90N User Manual

Page 9

background image

www.statewaterheaters.com 9

Capacity, Gas and Electrical Characteristics

Model

Approx. Capacity

Input

Gas

Type

Gas Supply Pressure

Manifold Pressure

Electrical Characteristics

U.S. Gals.

Litres

BTU/hr

Max.

in. WC (kPa)

Min.

in. WC (kPa)

in. WC (kPa)

Volts/Hz

Amperes

GPH-90N

25

94.6

100,000

Nat.

14.0 (3.49)

5.0 (1.25)

4.2 (1.05)

120/60

2.5

Minimum gas supply pressure must be maintained under both load and no load (dynamic and static) conditions.
Manifold Pressure is preset on the gas valve by the manufacturer; DO NOT ATTEMPT TO ADJUST!
Thermal effi ciency is 90%.
If the hardness of your water supply is more than of 12 grains per gallon (200 mg/L), if your water supply is acidic or otherwise impure,
the water supply must be treated with approved methods in order to ensure full warranty coverage. Problems resulting from the forma-
tion of scale are not covered by the warranty.

Minimum Clearance To Combustibles

Service Clearance

Test Pressure

P.S.I.

Top

Front

Vent

Back

Sides

Floor

Front

Sides

0

0

0

0

0

0

21” (53.3 cm)

12” (30.5 cm)

300

This appliance must be installed in accordance with local codes or, in the absence of local codes, the “National Fuel Gas Code” ANSI
Z223.1/NFPA 54 or the “Natural Gas and Propane Installation Code” CAN/CSAB149.1.
Not for installation in a Manufactured Home (Mobile Home).
This water heater is suitable for water (potable) heating only.
This water heater is suitable for installation in a closet or alcove.

ROUGH IN DIMENSIONS

FIGURE 2

INSTALLATION CONSIDERATIONS

Left Side View

Top View