beautypg.com

Plumbing – Airstream 2007 Safari User Manual

Page 59

background image

F

F - 2

PLUMBING

AUTOMATIC GAS REGULATOR

All models are equipped with a two stage automatic change over gas regulator that

offers the convenience of automatic changeover from empty to full gas cylinders. Both

tanks are connected to this regulator.

Make sure there is propane in both tanks before you start. Rotate the black lever on

the top front side of the regulator toward the cylinder you want to use first. This will be

the “service” cylinder and the other will be the “Reserve” cylinder. Slowly open both

cylinders valves. Open both cylinder valves completely, then close about 1/4 turn. This

will allow you to easily check to see if valves are open or closed. The indicator on top of

the regulator will turn bright green. The indicator will stay bright green as long as there

is fuel coming from the service cylinder. When the service cylinder empties, the regula-

tor will draw fuel automatically from the reserve cylinder providing an uninterrupted

fuel flow to the system. When it switches over, the indicator will change from green to

red. This red color indicates the service cylinder is empty and needs to be filled.

WARNING

: LP gas regulators must always be installed with the dia-

phragm vent facing downward. Regulators that are not in compartments have

been equipped with a protective cover. Make sure that regulator vent faces

downward and that cover is kept in place to minimize vent blockage, which could

result in excessive gas pressure causing fire or explosion.

WARNING

: The LPG bottles are securely mounted on the front “A”

frame of your trailer. If these bottles must be removed for service or replacement

it is important that they be reinstalled correctly in order to prevent any possibility

of their falling off or becoming dislodged during travel.

LPG BOTTLES

The following step-by-step procedure gives you the proper method of removing and

installing these bottles:

1. Turn the knob on your automatic regulator so the arrow points to the tank opposite

the one to be removed. Shut off the gas valve on the bottle to be removed.

2. Disconnect the rubber gas line at the bottle to be removed. (The green plastic fitting

is a right hand thread and no tools should be used.)

3. Turn the large clamping “T”’ handle counterclockwise until the hold down bracket

is loose enough to remove the bottle. If your trailer is equipped with a gas bottle

cover the “T”’ handle must be removed, and then remove the cover before remov-

ing the bottle.

DO NOT REMOVE THE CENTER HOLD DOWN ROD.

To Install

1. Place the bottle in position on the “A” frame and bottle cross member so that it

rests on the upper collar of both bottles with the collar rims engaged in the grooves

on the underside of the bracket. If your trailer is equipped with a gas bottle cover it

should be positioned over the bottles next. Make sure the hold down rod projects

up through the hole in the shroud center bracket.

2. Replace the “T” handle and tighten down until the bottles are held firmly in place.

3. Turn on gas shut off valves and test all fittings with a soap suds or detergent solution

and watch for bubbles.

If you have allowed both tanks to run out, air may have gotten into the lines. In this

event, the air must be forced out through the lines by gas pressure before you will be

able to light the pilots. Hold a match to the pilot of the appliance closest to the tanks

until it lights and stays lit. Then move to the next closest, etc.