PLUMBING

F - 1

LIQUID PETROLEUM GAS (LPG)

FILL VALVE

Your trailer is equipped with LP tank fill valves called “RV Type I Acme” connection.

The large, green, nylon swivel nut is a right hand thread and is designed for hand

operation only.

The valve features an internal spring-loaded module that will not allow gas to flow from

the cylinder until a positive seal has been made at the connection. The valve outlet

has 1-5/16” Acme threads on the outlet exterior and female POL, left-handed threads

on its interior. This feature allows for connection of the new wrenchless, right-handed,

Acme RV connection and still accommodates the standard left-handed POL fittings

used for filling propane cylinders.

The mating, green swivel nut and brass nipple also incorporates new features: the

green nylon nut swivels on a black bushing that is heat sensitive. Between 240 degrees

F. and 300 degrees F. the bushing will yield (melt) allowing the spring-loaded module in

the valve to push the brass nipple back (approximately 1/4”) closing the module and

stopping the flow of gas from the cylinder. Inside the brass nipple is a flow-limiting

device designed to sense excessive gas flow. If an excessive flow is sensed, the flow-

limiting device shuts the flow down to a maximum of 10 SCFH (Standard Cubic Feet

per Hour) or less. This is also referred to as the by-pass flow.

By-pass flow is extremely important in the proper operation of this connection. The

flow-limiting device may activate if the cylinder valve is opened quickly. When all

appliances are off, the by-pass flow allows the pressure downstream from the flow-

limiting device to equalize. When pressure is equalized, the flow-limiting device will

supply normal flow to the system. Equalization occurs in approximately 5 seconds

and in most cases goes completely unnoticed. If, however, an appliance is left on or

there is a leak or open flow in the system, the by-pass pressure will not be able to

equalize and allow the flow-limiting device to re-open. Symptoms of this condition

would be appliances that light but have lower than normal flame or starve out from

lack of gas, a substantial reduction in the flame when another appliance is operating,

or pilots that are difficult to light. If this should happen, the following steps should

eliminate the condition:

1. Close LP cylinder valve.

2. Extinguish all flames and smoking materials

3. Be sure all gas appliances, including their pilot lights, are off.

4. Open LP cylinder valve slowly. DO NOT SNAP OPEN.

5. Wait at least 15 seconds before lighting appliances.

6. If operational difficulties continue, there may be a leak in the system. Immediately

close the LP cylinder valve and have the system inspected by a qualified RV

service technician.

Again, make sure all appliances are off before opening propane cylinder valves.

Exception: when reconnecting a full cylinder to an auto changeover regulator

it is not necessary to shut off the appliances or close the valve of the cylinder

already in service.

WARNING

: LEAKING LP GAS MAY IGNITE CAUSING A FIRE OR

EXPLOSION WHICH COULD RESULT IN SERIOUS BODILY INJURY,

PROPERTY DAMAGE, AND/OR DEATH.

How long a full tank of gas will last is dependent on usage. In cold weather, when you

are using the furnace, large amounts of hot water, and are doing extensive cooking,

you will naturally use more than you will in warm weather when you may do limited

cooking. On the average, with normal cooking and other appliance use you can prob-

ably count on two to three weeks of service from each tank.