Persistent serial commands – AMX MIO R-1 AUDIO FG147-04 User Manual
Page 14
![background image](/manuals/40483/14/background.png)
Programming The MIO R-1 AUDIO
10
MIO R-1 AUDIO
Persistent Serial Commands
There are a select number of persistent commands the MIO R-1 AUDIO recognizes. Establish a
HyperTerminal session with your device to use the following commands:
Serial Commands
@BRT
Set Brightness level
Syntax:
"'BRIT- level>'" Variables: (1) "'@BRT-16'" Sets the awake brightness level to 50%. (2) "'@BRT-32,5'" Sets the awake brightness level to 100% and sleep brightness level to IRMODE # Sets the IR transmission frequency to either 455KHz or 38KHz. "IRMODE #" Variables: "IRMODE 455" Sets the IR transmission frequency to 455KHz. SLEEP-# Force the device into screen saver mode. "'SLEEP-#'" (timed sleep; a persistent command) Variables: SEND_COMMAND Panel,"'SLEEP-45'" Forces the device into screen saver mode after 45 seconds.
brightness level # = a value from 0 - 32.
"'@BRT-#'" (Set LED Awake brightness level)
"'@BRT-#,#'" (Set LED Awake brightness level, sleep brightness level)
Example:
approximately 15%
Syntax:
# = 455 or 38
Example:
Syntax:
# = 0 - 60 in seconds; time to wait before going to sleep. Default is 30. 0 sets
the device to never sleep.
Example: