If ThE INvERTER fUSE BLOWS

8.

Your power inverter is fitted with a fuse, which should not have to be replaced under

normal operating conditions. A blown fuse is usually caused by reverse polarity or a

short circuit within the device or equipment being operated.
If the fuse does blow, take the inverter to a qualified technician for repair.

TROUBLEShOOTINg

9.

PROBLEM

REASON

SOLUTION

Alarm is On

Display shows . Device

has a short circuit or

demands too much surge

power.

Display shows . 12-volt

battery is too low.

Display shows voltage in

between 10.5 and 11.0-volts.

Display shows . 12-volt

voltage is too high.

Cycle the inverter power OFF

and ON.

If problem persists, use a

larger inverter or a smaller

device.

Remove the defective device.

See warranty and call

Customer Service 1-800-732-

7764 (Hours 7:00 am to 5:00

pm CST).

Recharge/replace battery

12-volt battery is low.

Recharge/replace battery.

The inverter will automatically

shut off after battery voltage

reaches 10.5-volts.

If in a vehicle, repair/replace

the alternator or charging

system.

Use a properly sized and

rated 12-volt battery.

If the input voltage returns to

15-volts or less, the inverter

will automatically restart.