Alarms: A separate alert tone will sound for each
band of Radar encountered with a different colored
light illuminated, (K/Ka-Green), (X-Red), (2, 3, 4-
Red). The signal strength indicators are the numbers
2, 3 and 4, the stronger the signal the more numbers
indicated will light up. Tone frequency will increase
as signal strength becomes stronger. All alarm lights
(X, K/Ka, 2, 3, 4) will flash when Laser is detected.
Signal Strength: Signal Strength will be first
indicated by the illumination of the LED of the band
detected, then the three numbers 2, 3, and 4 red
LED’s. When all three are illuminated the signal is
strongest.
VG-2: VG-2 detection is indicated with a separate
alarm along with the yellow power light (P)
blinking.
The C435 is always undetectable by VG-2/VG3.
Diagnostics: The RMR-C435 has a full internal
automatic diagnostic system. If the power light goes
off and remains off, check the 2-amp fuse in the
power cord by unscrewing the silver tip and
removing the fuse. If the fuse is good (wire inside
the fuse unbroken), return the unit for service.