Appendix e: monitor arming commands, Monitor arming commands – American Dynamics AD2089 User Manual
Page 51
Monitor Arming Commands
43
Appendix E: Monitor Arming Commands
Monitors are armed for alarm call up with codes that specify the following three parameters:
1 The display method (single, dual, or block monitors).
2 The queuing method (sequence or hold)
3 The clearance method (instant, auto, or manual)
To arm a monitor with a AD2089 keyboard:
1 Call the monitor to be armed.
2 Turn the keyswitch to the PROGRAM position.
3 Enter the monitor arming code number (see table)
4 Press the F2 key.
A keyboard operator can also program any monitor armed for instant or auto clearance, for
clearance via manual override. Manual override is enabled or disabled after the arming code is
programmed. If enabled, an “A” will appear after the three-letter acronym for the arming code that
appears on the monitor status line.
When using the AD1024 matrix switcher/controller system, monitors can be armed through S3
system setup software with a PC interface, or through the AD1024 embedded software with the
AD2089 keyboard. Following is a table of monitor arming codes and the commands that enable
the codes.
Monitor Arming Codes
Monitor Acronym
Command Sequence
Display Arming Status
see entries below
300, F2
Single, Sequence, Instant
SSI
301, F2
Single, Sequence, Auto
SSA
302, F2
Single, Sequence, Manual
SSM
303, F2
Single, Hold, Instant
SHI
304, F2
Single, Hold, Auto
SHA
305, F2
Single, Hold, Manual
SHM
306, F2
Block, Sequence, Instant
BSI
307, F2
Block, Sequence, Auto
BSA
308, F2
Block, Sequence, Manual
BSM
309, F2
Block, Hold, Instant
BHI
310, F2
Block, Hold, Auto
BHA
311, F2
Block, Hold, Manual
BHM
312, F2
Dual, Hold, Instant
Dual, Sequence, Instant
DHI/DSI *
313, F2
Dual, Hold, Auto
Dual, Sequence, Auto
DHA/DSA *
314, F2
Dual, Hold, Manual
Dual, Squence, Manual
DHM/DSM *
315, F2
Disarm Monitor
316, F2