Specifications
Electrical rating: 24 Volt AC (18-30 VAC)
1 amp maximum load per terminal (relay outputs)
4 amp total maximum load (all terminals combined)
Temperature control range: 45°- 90°F (7°- 32°C)
Accuracy: +/-1.0°F (+/-0.5°C)
Power Source: 24 VAC
Auto Changeover deadband: Selectable 2° to 8°F
Temporary temperature override: 3 hour maximum or next setpoint
Remote sensor capable: 1 indoor and 1 outdoor sensor
System configurations: Multi-stage gas, oil or electric
heating/cooling systems
Terminations: R, W1, W2, Y1, Y2, B, O, G, C, IS, OS, 1, 2
Other Multi-Stage
Heat / Cool Thermostats
9715i: Programmable, 7 Day
9615: Programmable, 7 Day
9415: Non-Programmable
Shipping Information
Indiv. Ctn. Dim.: 6.625" x 4.25" x 1.625"
Master Ctn. Qty.: 6
Master Ctn. Dim.: 9.25" x 5.625" x 7.5"
Master Ctn. Cu. Ft.: .23
Master Ctn. Wt.: 3.5 lbs.
Max. Pallet Qty.: 1260
Max. Pallet Wt.: 785 lbs.
Optional Sensors:
REMOTE INDOOR
REMOTE OUTDOOR
Distributed by:
Remote
Outdoor
Sensor
Remote
Indoor
Sensor
24 VAC
Common
Cooling
Relay
(Stage 1)
Heat Active
Reversing
Valve
Heating
Relay
(Stage 1)
Cool Active
Reversing
Valve
24 VAC
Transformer
Fan
Relay
OS
IS
C
Y1
B
O
Heating
Relay
(Stage 2)
W2
R
Cooling
Relay
(Stage 2)
Y2
G
Dry Contact
Relay
Dry Contact
Relay
2
1
Honeywell, Inc.*
T7300F
Carrier Corp.*
P374-2300, 33CS071-01
THE ROBERTSHAW
REPLACES:
9915
i
®
9020
i
9025
i
Item 9020i and 9025i Remote Sensors
Indiv. Ctn. Dim.: 2.625" x 1.5625" x 4.4375"
Master Ctn. Qty.: 6
Master Ctn. Dim.: 5.625" x 5.125" x 5.125"
Master Ctn. Cu. Ft.: .09
Master Ctn. Wt.: .78 lbs.
DELUXE
PROGRAMMABLE
THERMOSTAT
9915
i
Climate Controls Americas
515 South Promenade Avenue
Corona California 92879-1736 USA
Telephone +1 800 304 6563 Facsimile +1 800 426 0804
Outside the USA +1 630 260 3402
Patents Pending www.icca.invensys.com
©2004 Climate Controls Americas 5/04 - #150-1761B
E
G
ELECTRIC
O
OIL
GAS
Feature Comparison
Robertshaw Honeywell, Inc.
Carrier Corp.
9915i
T7300F
P374-2300
Manual Override
X
X
X
EEPROM
X
X
X
Compressor Short Cycle Protection
X
X
X
7 Day Programming
X
X
X
Resume
X
X
X
Auto Changeover
X
X
X
Line Powered
X
X
X
Programmable Fan
X
X
X
O & B Terminals
X
X
Partial
°F and °C
X
X
X
Status Indicators
X
X
X
Adjustable Differential
X
X
X
Gas/Electric
X
X
X
Dry Contact Relays
X
X
X
Energy Efficient Recovery
X
X
X
24V Contact Relay
X
Pre-Set Program
X
X
X
4 Hour Reserve
X
X
X
Events / day
2, 4, 6
4
4
Hidden Service Level
X
X
X
Remote Outdoor Sensor
X
X
X
Security Key Pad
X
X
X
Vacation Setting
X
X
X
Air Filter Monitor
X
X
X
12 or 24 Hour
X
X
Remote Indoor Sensor
X
X
Large Display
X
X
Back Lighting
X
X
X
Adjustable Purge Cycles
X
Service Interval Reminders
X
On Screen Contractor ID Service Reminder
X
5/2 Day Programming
X
Adjustable Residual Cooling
X
1/2 Degree Resolution
X
Menu Driven (Ease of Programming)
X
24 Hr. Programming
X