Manley СORE REFERENCE CHANNEL STRIP - MCORE001-025 4/2014 - 5/2014 User Manual
Page 12

VR15 VR12
VR16
GR-METER
LIM CV
LIM REF V OP1 ZERO VU
Diagram 8
14. Servicing
VR11
VR9
VR6
GR-ZERO
12AX7WA
6922
GR-AUDIO
TUBE LOCATION
CALIBRATION TRIM POT LOCATION
c
o
r
e
The CORE requires calibration for 3 sections of its circuitry:
I) - VU METER- Adjust: +4dBu (1.228 Volts RMS) = “0” VU, Meter “GR” zero set
®
ii) - ELOP COMPRESSOR- Adjust: Gain Reduction (Audio & Meter GR)
iii)- FET PEAK LIMITER- Adjust: reference voltage & FET control voltage
Tools required:
-
Audio Tone Generator (oscillator)
-
Audio Analyzer or a voltmeter capable of reading both DC & AC voltages.
Initial settings:
-
Mic/Line Input select switch: Out = LINE IN Enable
-
120Hz HP filter switch: Out = Disable
-
Gain switch: Out = LOW
-
48V Phantom switch: Out = OFF
-
Phase Invert switch: Out = 0
-
Input Level Attenuator: Set at Minimum
-
Compressor Section: Switch = Bypass; Compression, Attack & Release =12:00 O'clock
-
Shelving EQ section: High/Low controls set both = 12:00 O'clock.
-
Mid EQ section: Boost/Cut control = 12:00 o'clock, Frequency range select switch = 100Hz-1kHz,
Frequency sweep control = MIN
-
Peak Limiter section: Limiting = MIN, Release = 12:00 o'clock
-
Output Gain Control: 12:00 o'clock
15. Core Calibration Procedure
2A (T) FUSE
11