1. Overview
The TC-4 device is 4 channel thermocouple interface device for a MTS Log Chain. The TC-4 may
also be used as a stand-alone 4 channel MTS compatible thermocouple amplifier (see Chapter 2
for more details).
Each of the four inputs of the TC-4 can be user configured either EGT range (32..1999 degF,
0..1093 degC) or for CHT range to measure cylinder head temperatures (32..572 degF, 0..300
degC.
2. Specifications
Power
Power requirements
8-36 Volt / 50mA
see Note 1
Power reversal protection
Yes
External Sensor power
5V (+- 2.5%), 300mA max.
Serial Communication
Serial Port Speed
19.2 kbit/sec
Packet/Logging Speed
81.92 msec/sample packet
Sample Resolution
10 bits (0..5V at 0.1% resolution)
Input Specifications
Number of Channels
4
Thermocouple Type
Type K
Input measurement range
0 to 300 degC (CHT Range) or
0 to 1093 degC (EGT Range)
CHx+ max input voltages
- 2.5V to +7.5V
CHx- max input voltages
-2.5V to +7.5V
Common Mode Rejection
Range
-2.5V to +7.5V
Input Impedance
1 MOhm
Temperature
Max Operating Temperature
-20 to +80 deg Celsius
Mechanical
Size (W x L x H)
133 x 65 x 26 mm
Weight 114
grams
Note 1: Supply current does not included current of external sensors powered from the 5V output