DC VOLTS
RESISTANCE (OHMS)
DIODE/CONTINUITY TEST
DC AMPS
4
E
Range
Resolution
Accuracy
Overload
Protection
200mV
100
µ
V
500V DC
2V
1mV
±(0.8% of reading
or AC
20V
10mV
+ 5 digits)
500V RMS
500V
1V
Input impedance: 10M
Ω
for all ranges.
Range Resolution
Accuracy
Overload
Protection
200
Ω
0.1
Ω
±(1% of reading
2K
Ω
1
Ω
+ 5 digits)
250V DC/AC RMS
200K
Ω
10
Ω
20M
Ω
10K
Ω
±(2% of reading
+ 5 digits)
Function
Range Resolution
Accuracy
Overload
Protection
Diode test
1mV
Displays,
voltage drop
250V
approximation
DC/AC
Continuity 1
Ω
50
Ω
or less,
RMS
test
buzzer (beeper)
will sound
Range Resolution
Accuracy
Overload
Protection
2mA
1
µ
A
20mA
10
µ
A
±(1.5% of reading
0.315A/250V fuse
200mA
100
µ
A
+ 5 digits)
10A
10
µ
A
±(2% of reading
Non-Protected
+ 5 digits)
Measuring time is equal to or less than 15 seconds and time