BATTERY TEST (LEDs)

DIODE/CONTINUITY TESTS

5

Function

Range Resolution

Description

Note

Diode Test

2V

1mV

Test Current:
1±0.6mA
Test Voltage:

Overload

Approx. 1.5V

Protection:

Continuity 200

0.1

Approx. 120

or 250V DC or

Test

less, buzzer

AC RMS

(beeper) will
sound

E

When the voltage of the battery being tested is lower than
10% of its rated voltage, the red LED will not light.

Load

Range Resolution Current Accuracy

Notes

Green LED: 1.30V
±0.075V and up.
Yellow LED: 0.94V

1.5V

0.001V

10mA

±0.075V to 1.29V

(approx.)

±0.075V.
Red LED:0.15V±0.075V
to 0.93V±0.075V

Green LED: 5.22V
±0.3V and up.
Yellow LED: 3.76V

6V

0.01V

100mA

±0.3V to 5.21V±0.3V.

(approx.) ±(5% of

Red LED:0.6V±0.3V to

reading

3.75V±0.3V

+ 5 digits) Green LED: 7.83V

±0.45V and up.
Yellow LED: 5.64V

9V

0.01V

10mA

±0.45V to 7.82V±0.45V.

(approx.)

Red LED:0.9V±0.45V to
5.63V±0.45V

Green LED: 10.44V
±0.6V and up.

12V

0.01V

200mA

Yellow LED: 7.52V

(approx.)

±0.6V to 10.43V±0.6V.
Red LED:1.2V±0.6V to
7.51V±0.6V