AC VOLTS
RESISTANCE (OHMS)
DC AMPS
AC AMPS
4
Range
Resolution Accuracy
Notes
20.00mA 10
µ
A
±
(1.0% of Overload Protection: Fuse
reading
315mA/250V
200.0mA 100
µ
A
+ 5 digits) Input Voltage Drop: <0.2V.
2.000A
1mA
±
(2.0% of Unfused; 15sec maximum
reading
Input Voltage Drop: <0.2V.
*10.00A
10mA
+ 5 digits)
*A waiting period of at least 15 minutes is necessary between
every 15 second testing period.
Range
Resolution Accuracy
Notes
20.00mA 10
µ
A
±
(1.5% of Overload Protection: Fuse
200.0mA 100
µ
A
reading
315mA/250V
+ 5 digits) Input Voltage Drop: <0.2V.
E
Range
Resolution Accuracy
Notes
2.000V
1mV
±
(1.2% of
Input Resistance: 10M
Ω
20.00V
10mV
reading
Overload Protection: 600V DC
200.0V
100mV
+ 5 digits)
or AC 600V RMS.
600V
1V
Frequency Response:
50Hz - 400Hz
Range
Resolution Accuracy
Notes
200.0
Ω
100m
Ω
2000k
Ω
1
Ω
±
(1.0% of
20.00k
Ω
10
Ω
reading
Overload Protection: 250V DC
200.0k
Ω
100
Ω
+ 5 digits) or AC RMS.
2.000M
Ω
1k
Ω
20.00M
Ω
10k
Ω
±
(2.0% of
reading
+ 5 digits)