Installations – Cyron Lighting HTW1000 RGB User Manual
Page 3
certified custom electronic installers. Please contact CYRON Technical
Support for further details.
Installations _____
CONTROLLER should preferably be installed out of sight, while
planning for the IR receiver to be installed in line of sight. REMOTE
needs to be pointed at the IR receiver for operation. Cautions and
Common practices:
Keep the controller and wires away from extreme heat,
liquids, and moving objects.
Low voltage wires can be routed through walls and cabinets as
long as proper care is taken to avoid damages.
DO NOT modify internal components. Tampering with
components and wiring will void factory warranty.
The CONTROLLER operates on 100% regulated 12VDC power. The
size (wattage) of the power supply depends on the number of lights.
Refer to Table One for calculating the power supply ratings:
CYRON
Series/Size
Watts per
one
lightbar
Model no. available
(Qty)
LEDs per bar /
Type of LED
HT
(Standard)
/ 9”
1.44
HTB9 (2x9”)
18 / Superbright
60º
HT
(Standard)
/ 15”
2.40
HTB15 (2x15”)
HTB15-B10 (10x15”)
HTB15-5B10 (10x15”)
5ft cords
30 / Superbright
60º
HTP
(Pro)
/ 9”
1.20
HTPB9 (2x9”)
15 / Ultrabright
SMD 120º
HTP
(Pro)
/ 15”
2.16
HTPB15 (2x15”)
27 / Ultrabright
SMD 120º
HTP
(Pro)
/ 24”
3.60
HTPB24 (2x24”)
45 / Ultrabright
SMD 120º
HTPR / 12”
2.20
HTPR-F
9 / Tri-chip
SMD 120º
HTPR / 16.5feet
36.00
HTPB-RL
150 / Tri-chip
SMD 120º
__________ Table One __________