1.2.2 List of remote commands
Below are the lists of remote commands which can be executed remotely either by using Telnet or
HyperTerminal with a regular type of LAN cable connection to the PIM31 unit. It is recommended to
add “\r\n” at the end of each remote command if proprietary applications to execute the following
commands are used. This avoids problems to complete the command executions.
Command
Parameter
Return value
Unit
Description
*IDN?
Product, Model
*RST
F1
Frequency
1,0
MHz
1: True
,
0:False(Out
of
Range)
F2
Frequency
1,0
MHz
1: True
,
0:False(Out
of
Range)
P1
Power
1,0
dBm
1: True
,
0:False(Out
of
Range)
P2
Power
1,0
dBm
1: True
,
0:False(Out
of
Range)
ON, 1
1,0
1: True , 0:False
ALC
OFF,0
1,0
1: True , 0:False
BW
index
1,0
1: True , 0:False
ON, 1
1,0
1: True , 0:False
SET
RF
OFF,0
1,0
1: True , 0:False
STAtus
F1,F2,P1,P2,
ALC,BW,RF
F1
Frequency
MHz
F2
Frequency
MHz
P1
Power
dBm
P2
Power
dBm
ALC
1,0
BW
index
RF
1,0
ERRor
Last Error
Error Log of Last command
PIM
PIM, Order,
IM Frequency
GET
RSSI
RSSI