beautypg.com

Ashland I-175XL User Manual

Page 22

background image

COUNTERBALANCE VALVE

PURPOSE of the counterbalance valve is to prevent the front gate from closing before the

rear pushgate is fully retracted when the scraper is empty. This enables the operator to

start the next cut without having to reopen the gate from the closed position.

INSTRUCTIONS for establishing counterbalance valve setting:

When properly adjusted, the front gate will close 58% from full open position (26-1/2”

from bottom of gate to cutting edge) and hold at that position until the rear pushgate is

fully retracted. If the front gate is closing more than 58%, remove the acorn cap nut and

turn the adjusting screw clockwise until the front gate holds at that position. Turn an

additional ¼ turn clockwise, then tighten the lock nut. DO NOT turn the adjusting screw

more than is necessary to hold the front gate at 58% open.

22