Standard Two-Circuit Hydraulic Plumbing

The apron cylinders and the push-off cylinder are controlled on the same circuit with

the sequence of the operation controlled by a sequence valve. The other hydraulic

circuit controls the lift cylinders on the earthmover.

*To adjust the sequence valve, see Troubleshooting section.

Optional Three-Circuit Hydraulic Plumbing

The apron cylinders, push-off cylinder, and lift cylinders are all on separate hydraulic

circuits.

Push-off Cylinder Hydraulic System

A pressure relief valve, in both two-circuit and three-circuit hydraulic plumbing, pro-

tects the pushoff cylinder hydraulic system. This pressure relief valve is designed to

limit the hydraulic oil pressure delivered to the push-off cylinder. This valve is preset

from the factory at 2000 psi.

*To adjust the pressure relief valve, see Troubleshooting section.

CAUTION! Relieve all hydraulic pressure before working on the hydraulic

system.

WARNING!

High Pressure Fluid Hazard – To prevent serious injury or death

from high pressure fluid:

a) Relieve pressure on hydraulic system before repairing,

adjusting, or disconnecting.

b) Wear proper hand and eye protection when searching for

leaks.

c) Keep all components in good repair.