background image

4

INSTALLATION

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL
CODES.



RT-94085SL COMPONENTS


The RT-94085SL consists of the following components:
1) RT-980-1510

1) RT-980-1570

1) SR-20

1) PSR-2

1) RT-980-1530

1) RT-980-1590

5) PCSC/UPC-0.3

2) BPS-2

1)

RT-980-1550

1)

MTX-CWDM-8-MPD


The individual 980 series video rack cards that make up the RT-94085SL are combined in a
rack mount configuration using the SR-20 subrack. Please refer to the instruction manuals for
the SR-20 and the PSR-2 for information on the installation of the subrack with its power supply.
The individual 980 series rack cards can slide into any of the open slots in the SR-20 subrack,
however, the recommended configuration is shown below. This configuration starts with the
lowest wavelength card, the RT-980-1510, next to the PSR-2 power supply and ends with the
highest wavelength card, the RT-980-1590, at the left side of the rack. Following this
configuration allows the fiber port on the back of the 980 series card to best line up with its
associated port on the CDWM unit. Use a small screwdriver to push and lock the ¼ turn
fasteners into place. The Multi-Channel Digital Video CWDM that optically multiplexes the five
video rack cards used in the RT-94085SL is labeled MTX-CWDM-8-MPD. It should be mounted
directly below its corresponding SR-20 subrack with a ½ RU space between the two
components. To maximize the performance and life of the system, installing a fan above the
SR-20 subrack is recommended to pull air up across the RT-94085SL components.