Running a consistency check – Asus PIKE 2008 User Manual
Page 29
![background image](/manuals/400796/29/background.png)
ASUS PIKE 2008
2-15
4. Use the arrow key to select the disk you would like to configure as hot spare,
then move the cursor to the Hot Spr column. Press <+>, <->, or
Press
Hot Spare.
Running a consistency check
To run a consistency check on the RAID volume:
1. Follow steps 1–3 of the section Viewing volume properties and step 2 of
the section Managing hot spares.
2. From the Manage Volume screen select Consistency Check, then press
3. The below screen appears. Press
the RAID volume.
Esc = Exit Menu F1/Shift+1 = Help
SPACE/+/- = Change Item C = Commit Changes
LSI Corp Config Utility v7.05.01.00 (2010.02.09)
Manage Hot Spare -- SAS2008
Identifier LSI Logical Volume 3000
Type RAID 1
Size(GB) 73
Status Optimal
Task None
Slot Device Identifier Hot Drive Pred Size
Num
Spr Status Fail (GB)
0 ATA WDC WD800JD-22LS1D06 [No] RAID No 74
1 ATA WDC WD800JD-22LS1D06 [No] RAID No 74
2 ATA WDC WD800JD-22LS1D06
[No]
---------- No 74
3 ATA WDC WD800JD-22LS1D06
[No]
---------- No 74
Esc = Exit Menu F1/Shift+1 = Help
Enter = Select Item
LSI Corp Config Utility v7.05.01.00 (2010.02.09)
Manage Volume -- SAS2008
Press Enter to run a consistency check on the RAID volume.
This field is grayed out under the following conditions:
- The adapter’s MPT FW does not support the feature
- The volume is a RAID 0
- The volume is not optimal
- The volume is already running a consistency check
- The volume has a consistency check pending