beautypg.com

Running a consistency check – Asus PIKE 2008 User Manual

Page 29

background image

ASUS PIKE 2008

2-15

4. Use the arrow key to select the disk you would like to configure as hot spare,

then move the cursor to the Hot Spr column. Press <+>, <->, or .

Press to commit the changes. The Drive Status column field now shows

Hot Spare.

Running a consistency check

To run a consistency check on the RAID volume:
1. Follow steps 1–3 of the section Viewing volume properties and step 2 of

the section Managing hot spares.

2. From the Manage Volume screen select Consistency Check, then press

.

3. The below screen appears. Press to start the consistency check on

the RAID volume.

Esc = Exit Menu F1/Shift+1 = Help

SPACE/+/- = Change Item C = Commit Changes

LSI Corp Config Utility v7.05.01.00 (2010.02.09)

Manage Hot Spare -- SAS2008

Identifier LSI Logical Volume 3000

Type RAID 1

Size(GB) 73

Status Optimal

Task None

Slot Device Identifier Hot Drive Pred Size

Num

Spr Status Fail (GB)

0 ATA WDC WD800JD-22LS1D06 [No] RAID No 74

1 ATA WDC WD800JD-22LS1D06 [No] RAID No 74

2 ATA WDC WD800JD-22LS1D06

[No]

---------- No 74

3 ATA WDC WD800JD-22LS1D06

[No]

---------- No 74

Esc = Exit Menu F1/Shift+1 = Help

Enter = Select Item

LSI Corp Config Utility v7.05.01.00 (2010.02.09)

Manage Volume -- SAS2008

Press Enter to run a consistency check on the RAID volume.

This field is grayed out under the following conditions:

- The adapter’s MPT FW does not support the feature

- The volume is a RAID 0

- The volume is not optimal

- The volume is already running a consistency check

- The volume has a consistency check pending

This manual is related to the following products: