ZGP366NRSS (Natural Gas)
ZGP366LRSS (Liquid Propane)
GE Monogram
®
36" All-Gas Professional Range with 6 Burners
Dimensions and Installation Information (in inches)
Electrical Requirements
Ranges must be hooked up to a 120V, 60Hz properly
grounded dedicated circuit protected by a 15-amp circuit
breaker or time-delay fuse.
Universal Utility Locations
4-5/8”
13-3/8”
36”
11-3/8”
2”
2”
6-1/2”
Gas/
Electric
Gas/
Electric
Locate gas and
electric as shown
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order one with a 36"-wide range backsplash
ZX12B36PSS–12" backsplash
ZXADJB36PSS– 30"-36" adjustable height
Side View with a Backsplash
10-1/2”
1-1/2”
12”
28-1/4” to
Beveled
Edge of Control
Panel Bullnose
27-1/2” to
Beveled Edge
- Maximum
Adjacent
Cabinet Depth
for
Flush
Installation
13/16”
30-36”
3-3/16”
Control Panel
Depth
28-1/4”
to Front of
Door
48-1/4”
with Oven Door
Open
31-1/16”
to Front of
Handle
35-1/4”
to
36-3/4”
7” Control
Panel Height
28-7/8”
to Front
Edge
Optional
Backsplash
Accessories
Gas Supply
• The natural gas models are designed to
operate at 5" water column pressure.
For proper operation, the pressure of
the natural gas supplied to the regulator
must be between 7" and 13" water
column.
• The LP models are designed to operate
at 10" water column pressure. For
proper operation, the pressure of the LP
gas supplied to the regulator must be
between 11" and 13" water column.