Cutout and product dimensions
Advance planning for above-the-cooktop ovens (240 or 120)
with Advantium Speedcook technology
Above-the-cooktop Advantium oven
Dimensions (in inches)
66" MIN.
Mounting
height
from floor
30" MIN.
width required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-3/8 max
(Rear)
16 max
25-1/2
16 max
30 max
Minimum distance from
door hinge side to adjacent
wall should equal 1/2-inch.
13"
MAX.
12"
MIN.
(without
obstruction)
100˚
Door open
Cabinet Front
SIDE VIEW A-A
Cabinet Bottom Shelf
Filler Block
Self-Aligning Screw
Oven Top
Equivalent
to Depth of
Cabinet Recess
This distance can
NOT exceed 2” to
ensure proper
installation with
the provided
screws.
240V and 120V outlets
need to be spaced on
the side if the desire is
to setup with top
exhaust.
A
A
Note: Outside venting is optional. Vent (duct) can be
horizontal or vertical.
Dimensions and installation information
(in inches)
Hood exhaust duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust connection
The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct.
If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6"-diameter duct.
Rear exhaust
If a rear or horizontal exhaust is to be used, care should be taken
to align exhaust with the space between studs, or wall should be
prepared at the time it is constructed by leaving enough space
between the wall studs to accommodate exhaust.
Grille
Filter kit accessory
Filter kit
JX81D Recirculating
charcoal filter kit
To be used when the
Advantium oven cannot
be vented to the outside.
Maximum duct length
For satisfactory air movement, the total duct length of 3-1/4"
x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
Elbows, transitions, wall and roof caps, etc.
Present additional resistance to airflow and are equivalent to a
section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equiva-
lent length of all transitions and adaptors plus the length of all
straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.
Duct
Equivalent
A. Rectangular-to-round
5 ft.
Transition adaptor
B. Wall cap
40 ft.
C. 90° round elbow
10 ft.
D. 45° round elbow
5 ft.
E.
90° rectangular elbow
25 ft.
F.
45° rectangular elbow
5 ft.
G.
Roof cap
24 ft.