Advance planning for warming drawers – GE ZKD910SFSS User Manual
Page 2
30
A
2" Min.
Allow 5/8"
Overlap on
All Sides
B
10-1/2"
23-1/4"
23-1/2" Min.
Inside
1" Min. Above Toekick
Oven
Cutout
2x2 or 2x4
Anti-Tip Block
Against Rear
Wall, 9" From
Floor to
Bottom of
Block
9"
9-1/4"
605Dia111
1" Min. Above Toekick or Adjust
to Oven Installation Height
A
2" Min.
Allow 5/8"
Overlap on
All Sides
B
10-1/2"
23-1/4"
23-1/2" Min.
Inside
Oven
Cutout
9-1/4"
2x2 or 2x4
Anti-Tip Block
Against Rear
Wall, 9" From
Floor to
Bottom of
Block
9"
605Dia110
Advance planning for warming drawers
Installation below a single or double oven
The warming drawer may be installed below a single or double
oven. Observe the 1" minimum clearance above the toekick, or
5" above the floor.
Side-by-side installation
Install two warming drawers in separate cutouts. Allow 2"
minimum between cutouts.
Installation below a countertop
The warming drawer may be installed beneath a countertop.
Install the drawer 5" minimum above the floor or 1" above
the toekick. The recommended distance from the floor to the
bottom of the cutout is 23-1/4" for undercounter installation.
Installation below a cooktop
The warming drawer is approved for installation below
specified cooktop models. A solid barrier and an air gap
between the cooktop and the warming drawer are required.
See note below.*
Installation below a cabinet drawer
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4"-thick plywood. Allow at least 1/4" air
gap between the barrier and the top of the warming drawer.
Note: Additional clearance between cutouts may be
required. Check to be sure that oven supports, above the
warming drawer location, do not obstruct the required
interior 23-1/2" depth and 9-1/4" height.
* Note: When installing the warming drawer below a cooktop,
a solid barrier must be installed at least 1" from the lowest
point of the bottom of the cooktop burner box to the top of
the cutout. Use any solid material such as 1/4"-thick
plywood. Allow at least 1/4" air gap between the barrier
and the top of the warming drawer.
Dim. A
Dim. B
ZTD910 28-1/2" 30"
ZKD910
25-1/2"
26-3/4"
30" warming drawer
ZTD910SFSS Stainless steel
27" warming drawer
ZKD910SFSS Stainless steel
Dim. A
Dim. B
ZTD910 28-1/2" 30"
ZKD910
25-1/2"
26-3/4"
605Dia109
Electrical
Outlet 16" Max.
From Left Side.
Installat
ion Below
a Drawer
23-1/2" Min.
Solid Barrier
1/4"
Air Gap
25"
1-1/2"
Cabinet
Top
36"
Countertop
Height
1" Min.*
A
9-1/4"
Electrical Outlet
42" Max. From
Right Side.
Solid Barrier
See Note
Electrical Outlet
Flush With
Side of Cabinet
7" Max.
9"
Install
2x4 or 2x2
Anti-Tip Block
Against Rear
Cabinet Wall
9" From Floor
to Bottom
of Block
7"
Install a Solid Barrier
and a 1/4" Air Gap
Above Warming Drawer
2"
Min.
Side-by-Side Installation
605Dia107
Dim. A
ZTD910 28-1/2"
ZKD910
25-1/2"
Double
oven
Single
oven