30

A

2" Min.

Allow 5/8"

Overlap on

All Sides

B

10-1/2"

23-1/4"

23-1/2" Min.

Inside

1" Min. Above Toekick

Oven

Cutout

2x2 or 2x4

Anti-Tip Block

Against Rear

Wall, 9" From

Floor to

Bottom of

Block

9"

9-1/4"

605Dia111

1" Min. Above Toekick or Adjust

to Oven Installation Height

A

2" Min.

Allow 5/8"

Overlap on

All Sides

B

10-1/2"

23-1/4"

23-1/2" Min.

Inside

Oven

Cutout

9-1/4"

2x2 or 2x4

Anti-Tip Block

Against Rear

Wall, 9" From

Floor to

Bottom of

Block

9"

605Dia110

Advance planning for warming drawers

Installation below a single or double oven
The warming drawer may be installed below a single or double
oven. Observe the 1" minimum clearance above the toekick, or
5" above the floor.

Side-by-side installation
Install two warming drawers in separate cutouts. Allow 2"
minimum between cutouts.

Installation below a countertop
The warming drawer may be installed beneath a countertop.
Install the drawer 5" minimum above the floor or 1" above
the toekick. The recommended distance from the floor to the
bottom of the cutout is 23-1/4" for undercounter installation.

Installation below a cooktop
The warming drawer is approved for installation below
specified cooktop models. A solid barrier and an air gap
between the cooktop and the warming drawer are required.
See note below.*

Installation below a cabinet drawer
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4"-thick plywood. Allow at least 1/4" air
gap between the barrier and the top of the warming drawer.

Note: Additional clearance between cutouts may be
required. Check to be sure that oven supports, above the
warming drawer location, do not obstruct the required
interior 23-1/2" depth and 9-1/4" height.

* Note: When installing the warming drawer below a cooktop,

a solid barrier must be installed at least 1" from the lowest
point of the bottom of the cooktop burner box to the top of
the cutout. Use any solid material such as 1/4"-thick
plywood. Allow at least 1/4" air gap between the barrier
and the top of the warming drawer.

Dim. A

Dim. B

ZTD910 28-1/2" 30"
ZKD910

25-1/2"

26-3/4"

30" warming drawer

ZTD910SFSS Stainless steel

27" warming drawer

ZKD910SFSS Stainless steel

Dim. A

Dim. B

ZTD910 28-1/2" 30"
ZKD910

25-1/2"

26-3/4"

605Dia109

Electrical

Outlet 16" Max.

From Left Side.

Installat

ion Below

a Drawer

23-1/2" Min.

Solid Barrier

1/4"

Air Gap

25"

1-1/2"

Cabinet

Top

36"

Countertop

Height

1" Min.*

A

9-1/4"

Electrical Outlet

42" Max. From

Right Side.

Solid Barrier

See Note

Electrical Outlet

Flush With

Side of Cabinet

7" Max.

9"

Install

2x4 or 2x2

Anti-Tip Block

Against Rear

Cabinet Wall

9" From Floor

to Bottom

of Block

7"

Install a Solid Barrier

and a 1/4" Air Gap

Above Warming Drawer

2"

Min.

Side-by-Side Installation

605Dia107

Dim. A

ZTD910 28-1/2"
ZKD910

25-1/2"

Double

oven

Single

oven

This manual is related to the following products: