Electrical requirements, Gas supply, Side view with a backsplash – GE ZGP304NRSS User Manual
Page 2: Additional clearances

14
Advance planning for 30" all-gas Professional ranges
All Professional ranges are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.
Conversion kits are included with the range if the wrong gas
type was ordered. WB28K10553 high-altitude kit for operation
above 6,000 feet is also available. The kits must be installed by
a qualified service technician at additional cost.
Electrical requirements
Ranges must be connected to a 120V, 60Hz properly grounded
dedicated circuit protected by a 15-amp circuit breaker or
time-delay fuse.
Gas supply
• The natural gas models are designed to operate at 5" water
column pressure. For proper operation, the pressure of the
natural gas supplied to the regulator must be between 7"
and 13" water column.
• The LP models are designed to operate at 10" water column
pressure. For proper operation, the pressure of the LP gas
supplied to the regulator must be between 11" and 13"
water column.
Locate gas
and electrical
as shown.
Product dimensions and clearances
The serial and model numbers are located behind the far left
knob for convenience. The full rating label is located on the
bottom of the control panel—visible when the oven door is open.
Backsplash accessories
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order ZX12B30PSS, 12" backsplash
Order ZXADJB30PSS, 30"-36" adjustable-height backsplash
with warming shelf
Side view with a backsplash
10-1/2”
1-1/2”
12”
28-1/4” to
Beveled
Edge of Control
Panel Bullnose
27-1/2” to
Beveled Edge
- Maximum
Adjacent
Cabinet Depth
for
Flush
Installation
13/16”
30-36”
3-3/16”
Control Panel
Depth
28-1/4”
to Front of
Door
48-1/4”
with Oven Door
Open
31-1/16”
to Front of
Handle
35-1/4”
to
36-3/4”
7” Control
Panel Height
28-7/8”
to Front
Edge
Optional
Backsplash
Accessories
Additional clearances
Installations without a hood require 48" minimum to combustibles.
A custom hood installation with exposed horizontal combustible
surfaces must have an “auto-on” feature. See hood installation
instructions for specific hood clearances.
The surface of the entire back wall above the range and below
the hood must be covered with a non-combustible material such
as metal, ceramic tile, brick or stone.