ofessional ranges

Advance planning for 36" dual-fuel Professional ranges

36" range cooktop configurations

The 36" Professional dual-fuel ranges offer a combination of
grill, griddle and burners on top, and a large self-clean, electric
European Reverse-Air convection and six-element heating
system oven.

Product dimensions and clearances

A 36" or wider HVI certified vent hood with 600 CFM minimum
is recommended. Models with a grill require a vent hood.

Backsplash accessories

The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required for
installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.

Order ZX12B36PSS, 12" backsplash
Order ZXADJB36PSS, 30"–36" adjustable-height backsplash
with warming shelf

Side view with a backsplash

ZDP364NDPSS
with 4 burners and griddle
(Order ZDP364LDPSS for LP gas)

ZDP364NRPSS
with 4 burners and grill
(Order ZDP364LRPSS for LP gas)

ZDP366NPSS
with 6 burners
(Order ZDP366LPSS for LP gas)

The serial and model numbers are located behind the far
left knob for convenience. The full rating label is located
on the bottom of the control panel—visible when the oven
door is open.

Additional clearances

Installations without a hood require 48" minimum to combustibles.
A custom hood installation with exposed horizontal combustible
surfaces must have an “auto-on” feature. See hood installation
instructions for specific hood clearances.

The surface of the entire back wall above the range and below
the hood must be covered with a non-combustible material such
as metal, ceramic tile, brick or stone.

36"

pr

ofessional ranges

48"

pr

ofessional ranges

10-1/2”

1-1/2”

12”

28-1/4” to

Beveled

Edge of Control

Panel Bullnose

27-1/2” to

Beveled Edge

- Maximum

Adjacent

Cabinet Depth

for

Flush

Installation

13/16”

30-36”

3-3/16”

Control Panel

Depth

28-1/4”

to Front of

Door

48-1/4”

with Oven Door

Open

31-1/16”

to Front of

Handle

35-1/4”

to

36-3/4”

7” Control

Panel Height

28-7/8”

to Front

Edge

Optional

Backsplash

Accessories