This compactor is designed as a built-in appliance
only. It may be located in any convenient space
under a countertop.
DO NOT OPERATE FREE-STANDING because the compactor
will tip over when the drawer is pulled out.
Additional Specifications: A 115 Volt, 60 Hz. power supply
is required. An individual properly grounded branch circuit
protected by a 15- or 20-amp circuit breaker or time delay
fuse is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
outlet location is critical for proper cord storage when
compactor is installed.
If the compactor is to be located in or near a corner of base
cabinets, allow 6” minimum clearance from the corner for
bag removal on the right side.
Install a 3/4" thick custom drawer panel/handle onto the
ZCGP150RII. for planning purposes, you may order the
template, Pub. No. 31-30597 in advance. The maximum
panel weight is 12 lbs.
Front View (not to scale)
ZCGP150RII -
GE Monogram
™
15" Built-In Compactor
for Custom Panels
14-7/8"
29-5/16"
3/4"
Thick
Custom
Panel
33-3/4"
min. to
35" max.
34" to 35"
15"
min.
24"
min.
14-7/8"
23-1/2" case/door depth
excluding custom panel
3" min. from
either side
Locate the
outlet 18" min.
from the floor.
33-3/4"
min. to
35" max.
34" to 35"
15"
min.
24"
min.
14-7/8"
23-1/2" case/door depth
excluding custom panel
3" min. from
either side
Locate the
outlet 18" min.
from the floor.
Clearances: Allow 6"
clearance to a vertical
wall on the right side
for bag removal. Allow
23" at the front for a full
drawer opening.