Backsplash accessories, Side view with a backsplash – GE ZGP486LDRSS User Manual
Page 3

monogram.com
7
48"
pr
ofessional ranges
36"
pr
ofessional ranges
30"
pr
ofessional ranges
Additional clearances
Installations without a hood require 48" minimum to
combustibles. A custom hood installation with exposed
horizontal combustible surfaces must have an “auto-on”
feature. See hood installation instructions for specific
hood clearances.
The surface of the entire back wall above the range and
below the hood must be covered with a non-combustible
material such as metal, ceramic tile, brick or stone.
10-1/2”
1-1/2”
12”
28-1/4” to
Beveled
Edge of Control
Panel Bullnose
27-1/2” to
Beveled Edge
- Maximum
Adjacent
Cabinet Depth
for
Flush
Installation
13/16”
30-36”
3-3/16”
Control Panel
Depth
28-1/4”
to Front of
Door
48-1/4”
with Oven Door
Open
31-1/16”
to Front of
Handle
35-1/4”
to
36-3/4”
7” Control
Panel Height
28-7/8”
to Front
Edge
Optional
Backsplash
Accessories
Backsplash accessories
The range requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom,
non-combustible backsplash can be used.
Order ZX12B48PSS, 12" backsplash Order
ZXADJB48PSS, 30"–36" adjustable-height backsplash
with warming shelf
Side view with a backsplash