GE JTP90DPBB User Manual
Jtp90dp, 30" built-in double microwave/thermal wall oven, Specification revised 6/13
Listed by
Underwriters
Laboratories
Specification Revised 6/13
320131
For answers to your Monogram
®
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
service, 800.626.2000.
JTP90DP
GE
®
30" Built-In Double Microwave/Thermal Wall Oven
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cabinet 30"
A – Overlap of oven over side of edges of cutout
11/16"
B – Overlap of oven at top and bottom of cutout
1"
C – Overall of oven at top of cutout
1/2"
Oven
D – Overall depth*
23-1/2"
E – Overall height with trim
44"
Overall height without trim
43-1/2"
F – Overall width
29-3/4"
*Depth including door handle is approximately 26-6/10" min. to
26-9/10" max.
20''
28''
21''
A
F
A
B
C
CONDUIT
48-1/2"
CUTOUT
HEIGHT
42-3/16'' MIN.
42-1/4'' MAX.
CUTOUT
WIDTH
28-1/2'' MIN.
28-5/8'' MAX.
Minimum
cutout location
21-5/8''
from the floor
21" Minimum
Door Allowance
JUNCTION BOX
LOCATION
CABINET
WIDTH
30''
DOOR MUST BE
REMOVED BEFORE
INSTALLATION
MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.
THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.
D
CUTOUT DEPTH
23-1/2'' MIN.
E
Note: Cabinets installed adjacent to wall
ovens must have an adhesion spec of at
least a 194°F temperature rating.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
Door handle protrudes 3" from door face.
Cabinets and drawers on adjacent 45°
and 90° walls should be placed to avoid
interference with the handle.
Note: These ovens are not approved for
stackable or side-by-side installations.
Electric wall ovens are not approved for
installation with a plug and receptacle. They
must be hard wired in accordance with
installation instructions.
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cabinet 30"
A – Overlap of oven over side of edges of cutout
11/16"
B – Overlap of oven at top and bottom of cutout
1"
C – Overall of oven at top of cutout
1/2"
Oven
D – Overall depth*
23-1/2"
E – Overall height with trim
44"
Overall height without trim
43-1/2"
F – Overall width
29-3/4"
*Depth including door handle is approximately 26-6/10" min. to
26-9/10" max.
20''
28''
21''
A
F
A
B
C
CONDUIT
48-1/2"
CUTOUT
HEIGHT
42-3/16'' MIN.
42-1/4'' MAX.
CUTOUT
WIDTH
28-1/2'' MIN.
28-5/8'' MAX.
Minimum
cutout location
21-5/8''
from the floor
21" Minimum
Door Allowance
JUNCTION BOX
LOCATION
CABINET
WIDTH
30''
DOOR MUST BE
REMOVED BEFORE
INSTALLATION
MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.
THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.
D
CUTOUT DEPTH
23-1/2'' MIN.
E
Dimensions and Installation Information (in inches)
KW Rating
240V
6.4
208V
5.6
Breaker Size
240V
30 Amps
208V
30 Amps