beautypg.com

Installation instructions, Normal vent long vent, Exhaust information – GE GTDS850GDWS User Manual

Page 6: Only these models, Parts available from local service organizations, Exhaust length

background image

Installation Instructions

6

7

6

EXHAUST INFORMATION

(cont.)

EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90 º

Elb ows

Rigid

Metal

Rigid

Metal

150 Feet
135 Feet
125 Feet
115 Feet

0

1

2
3

Use only for sho rt

run installations

4
5

105 Feet

95 Feet

125 Feet
115 Feet
105 Feet

95 Feet

85 Feet
75 Feet

NORMAL VENT

LONG VENT

EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90 º

Elb ows

Rigid

Metal

Rigid

Metal

90 Feet
60 Feet
45 Feet
35 Feet

0

1

2
3

Use only for sho rt

run installations

4

25 Feet

60 Feet
45 Feet
35 Feet
25 Feet

15 Feet

ONLY THESE MODELS

GTDL740EDWW
GTDL740GDWW

SEALING OF JOINTS

? All joints should be tight to avoid leaks. The male end of each

section of duct must point away from the dryer.

? The duct shall not be assembled with screws or other

fastening means that extend into the duct and catch lint.

? Duct joints can be made air and moisture-tight by wrapping

the overlapped joints with duct tape.

? Horizontal runs should slope down toward the outdoors

1/4 inch per foot.

INSULATION

Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce

condensation and

lint build-up.

HOOD OR WALL CAP

? Terminate in a manner to prevent back drafts or entry of birds

or other wildlife.

? Termination should present minimal resistance to the exhaust

air flow and should require little or no maintenace to prevent clogging

? Never install a screen in or over the exhaust duct. This could

cause lint build up.

? Wall caps must be installed at least 12 in. above ground level

or any other obstruction with the opening pointed down.

SEPARATION OF TURNS

For best performance, separate all turns by at least 4 ft. of straight
duct, including distance between last turn and exhaust hood.

TURNS OTHER THAN 90º

? One turn of 45º or less may be ignored.
? Two 45º turns should be treated as one 90º turn.
? Each turn over 45º should be treated as one 90º turn.

PARTS AVAILABLE FROM LOCAL SERVICE
ORGANIZATIONS

? Rigid Metal Duct Components

WX8X63

4

ʺ x 1ʹ Duct

WX8X64

4

ʺ x 2ʹ Duct

WX8X51

4

ʺ Elbow

WX8X59

4

ʺ Aluminum Hood

? Flexible Metal Duct Components

WX8X58

4

ʺ Clamps (2)

WX8X59

4

ʺ Aluminum Hood

WX08X10077

6

ʹ UL-Listed, Flexible Metal (Semi-Rigid)

Duct, 2 Clamps, 2 Close Elbows

WE1M454 Cover rear exhaust opening

For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the
chart.
The total vent system length includes all the straight portions
and elbows of the system (transition duct included).

This manual is related to the following products: