Installation instructions, Warning, Preparing for installation of new dryer – GE GTDL210GDWW User Manual
Page 2: Disconnecting gas, Removing lint from wall exhaust opening, Gas requirements, Dryer gas supply connection
![background image](/manuals/399654/2/background.png)
Installation Instructions
2
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU
Consideration must be given to provide adequate clearance for installation and service.
1
PREPARING FOR INSTALLATION
OF NEW DRYER
7,3,QVWDOO\RXUGU\HUEHIRUHLQVWDOOLQJ\RXUZDVKHU
This will allow better access when installing dryer
H[KDXVW
DISCONNECTING GAS
WARNING
- NEVER REUSE
2/')/(;,%/(&211(&7256
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOH
connectors when installing gas appliances.
REMOVING LINT FROM WALL EXHAUST
OPENING
• Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
INTERNAL DUCT
OPENING
CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD DUCTING MATERIAL.
REPLACE WITH NEW CSA(AGA)
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
2
GAS REQUIREMENTS
WARNING
• Installation must conform to local codes and
ordinances,or in their absence, the NATIONAL FUEL
GAS CODE,ANSI Z223.
• 7KLV JDV GU\HU LV HTXLSSHG ZLWK D 9DOYH %XUQHU
Assembly for use only with natural gas. Using conversion
NLW :(; \RXU ORFDO VHUYLFH RUJDQL]DWLRQ FDQ
FRQYHUW WKLV GU\HU IRU XVH ZLWK SURSDQH /3 JDV $//
&219(56,216 0867 %( 0$'( %< 3523(5/< 75$,1('
AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH
LOCAL CODES AND ORDINANCE REQUIREMENTS.
• The dryer must be disconnected from the gas supply
piping system during any pressure testing of that
V\VWHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
• The dryer must be isolated from the gas supply piping
V\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȺYDOYHGXULQJ
any pressure testing of the gas supply piping of test
SUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
DRYER GAS SUPPLY CONNECTION
• $LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer. Contact your local gas utility should you have
questions on the installation of the plugged tapping.
• 6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
room with the dryer.
• Use pipe thread sealer compound appropriate for
QDWXUDORU/3JDVRUXVH7HÀRQWDSH
• OLVWHGFRQQHFWRU$16,=&6$7KHOHQJWKRI the connect shall not exceed 3 ft. • &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\ • 2SHQVKXWRȺYDOYH • Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings ft. above sea level. • Installation must conform to local codes and ordinances or, in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223. ADJUSTING FOR ELEVATION 2" 2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY NOTE: Add to vertical dimension the distance between cabinet bottom to floor.
VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFK