GE PS950SFSS User Manual
Double oven slide-in electric range, Ps950sf/ef, Ge profile
PS950SF/EF
GE Profile
™
Series 30" Slide-In Double Oven Electric Convection Range
For answers to your Monogram
®
or GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
Specification Revised 7/14
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Listed by
Underwriters
Laboratories
Dimensions and Installation Information (in inches)
Receptacle Locations: Locally approved flexible service cord or
conduit must be used because terminals are not accessible after range
installation. See shaded area in drawing for location of electrical outlet box.
Recommended outlet locations allow range to be installed directly against
rear wall.
Note: This appliance has been approved for 0" spacing to adjacent
surfaces above the cooktop. However, a 6" minimum spacing to
surfaces less than 15" above the cooktop and adjacent cabinet is
recommended to reduce exposure to steam, grease splatter and heat.
Installation information: Before installing, consult installation
instructions for current dimensional data and additional
requirements.
MINIMUM DIMENSIONS BETWEEN COOKTOP, WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring and cabinets around the range can withstand the heat (up to 200°F)
generated by the range.
B. Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, or allow a 24"
minimum when bottom of wood or metal cabinet is protected by no less than 1/4" thick flame retardant millboard covered with not
less than No 28 MSG sheet metal, (.015"), .015" thick stainless steel, .024" aluminum or .020” copper. Acceptable electrical outlet
area. Orient electrical receptacle so the length is parallel to floor.
C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a 6" minimum spacing to
surfaces less than 15" above the cooktop and adjacent cabinet is recommended to reduce exposure to steam, grease splatter
and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be
avoided. If cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that
projects at least 5" beyond the front of the cabinets.
DOUBLE OVEN SLIDE-IN ELECTRIC RANGE
A
NOTE C
B
A
C
Both
Sides
*Depth including door handle is approximately 28-7/8".
29
7
⁄
8
”
36”
29
7
⁄
8
”
31
1
⁄
4
”
37
1
⁄
4
”
*28
7
⁄
8
”
25
7
⁄
8
”
45 ”
1
⁄
8
NOTE: Use a 4' power cord to prevent interference
with unit when installing.
MINIMUM DIMENSIONS BETWEEN COOKTOP, WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring and cabinets around the range can withstand the heat (up to 200°F)
generated by the range.
B. Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, or allow a 24"
minimum when bottom of wood or metal cabinet is protected by no less than 1/4" thick flame retardant millboard covered with not
less than No 28 MSG sheet metal, (.015"), .015" thick stainless steel, .024" aluminum or .020” copper. Acceptable electrical outlet
area. Orient electrical receptacle so the length is parallel to floor.
C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a 6" minimum spacing to
surfaces less than 15" above the cooktop and adjacent cabinet is recommended to reduce exposure to steam, grease splatter
and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be
avoided. If cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that
projects at least 5" beyond the front of the cabinets.
DOUBLE OVEN SLIDE-IN ELECTRIC RANGE
A
NOTE C
B
A
C
Both
Sides
*Depth including door handle is approximately 28-7/8".
29
7
⁄
8
”
36”
29
7
⁄
8
”
31
1
⁄
4
”
37
1
⁄
4
”
*28
7
⁄
8
”
25
7
⁄
8
”
45 ”
1
⁄
8
NOTE: Use a 4' power cord to prevent interference
with unit when installing.
* ADA qualified based
on Uniform Federal
Accessibility Standards
*
KW Rating
240V 15.2
208V 11.4
Breaker Size
240V 40 Amps
†
208V 40 Amps
†
†
Note: Check local codes for required breaker size.