Schematic diag ram of the range – Aga Ranges LEGACY 36 F104650-01 User Manual
Page 12

SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
12
Schematic diag
ram of the Range
Caution:
Label all wires pr
ior to disconnection when ser
vicing controls
.
Wir
ing errors can cause improper and dangerous
oper
ation.
V
e
ri
fy proper oper
ation after ser
vicing.
Code Descr
iption
BRE Broiler
elements
BSB Broiler
s
w
itch
b
loc
k
BTC Broiler
controller
CFM Cooling
fan
motor
IGS Ignition
s
w
itches
ISG Ignition
spar
k
gener
ator
LBE
Left hand bottom element
LFE
Left hand f
an element
LT
I
Left hand top inner element
LT
O
Left hand top outer element
LOS
Left hand o
v
en s
witch b
loc
k
NLI Neon
indicator
light
OFM
Ov
en f
an motor
OLS
Ov
en light s
witch
O
T
L
Left hand o
v
en ther
mostat
O
T
R
Right hand o
v
en ther
mostat
O
V
L
Ov
en light b
ulb
R
O
E
Right hand o
v
en element
RSB
Right hand o
v
en s
witch b
loc
k
TCK Timer
cloc
k
TCO
Ther
mal cut out
Code Color
BK Blac
k
BL Blue
BR Bro
wn
GY Gre
y
O Or
ange
R Red
V Violet
W White
Y Y
ello
w