Installation Instructions

5

CONNECTING THE DRYER TO HOUSE VENT

RIGID METAL TRANSITION DUCT
• For best drying performance, a rigid metal transition duct is

recommended.

‡ 5LJLGPHWDOWUDQVLWLRQVGXFWVUHGXFHWKHULVNRIFUXVKLQJDQG

kinking.

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
‡ ,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHWDO

VHPLULJLGGXFWLQJFDQEHXVHG.LW:;;

‡ 1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRURWK

er enclosed spaces.

‡ 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKRXOG QRW H[FHHG IHHW

(2.4m).

• For many applications, installing elbows at both the dryer

and the wall is highly recommended (see illustrations below).
Elbows allow the dryer to sit close to the wall without kinking
DQG RU FUXVKLQJ WKH WUDQVLWLRQ GXFW PD[LPL]LQJ GU\LQJ

performance.

• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
• In special installations, it may be necessary to connect the

GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH XVHG 21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG

ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition duct.

‡ ,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO

type) ducts that comply with the “Outline for Clothes Dryer
Transition Duct Subject 2158A” shall be used.

‡ 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU

other enclosed spaces.

‡ 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKRXOG QRW H[FHHG IHHW

(2.4m).

• Avoid resting the duct on sharp objects.
• For best drying performance:

1. Slide one end of the duct over the clothes dryer outlet pipe.
2. Secure the duct with a clamp.
With the dryer in its permanent position, extend the duct to

its full length. Allow 2” of duct to overlap the exhaust pipe.
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKW
DVSRVVLEOHIRUPD[LPXPDLUÀRZ

4. Secure the duct to the exhaust pipe with the other clamp.

DO

ELBOW HIGHLY
RECOMMENDED

ELBOWS HIGHLY
RECOMMENDED

DON’T

DO NOT USE

EXCESSIVE

EXHAUST

LENGTH

DO NOT

CRUSH

FLEXIBLE

EXHAUST

AGAINST

WALL

DO NOT

SIT DRYER

ON FLEXIBLE

EXHAUST

7

BATHROOM OR BEDROOM INSTALLATION

• The dryer MUST be vented to the outdoors. See EXHAUST

INFORMATIONVHFWLRQ

• The installation must conform with local codes or, in the

absence of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.

8

MOBILE OR MANUFACTURED HOME
INSTALLATION

• Installation MUST conform to the MANUFACTURED HOME

CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-
80
or, when such standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO.
501B.

• The dryer MUST be vented to the outdoors with the termination

securely fastened to the mobile home structure. (See EXHAUST
INFORMATION
VHFWLRQ

• The vent MUST NOT be terminated beneath a mobile or

manufactured home.

• The vent duct material MUST BE METAL.
• Do not use sheet metal screws or other fastening devices

which extend into the interior of the exhaust vent.

• See section 2 for electrical connection information.

6

ALCOVE OR CLOSET INSTALLATION

• If your dryer is approved for installation in an alcove or closet,

it will be stated on a label on the dryer back.

• The dryer MUST be vented to the outdoors. See the EXHAUST

INFORMATIONVHFWLRQV

• Minimum clearance between dryer cabinet and adjacent walls

or other surfaces is:

0 in. either side

LQIURQWDQGUHDU

‡ 0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV

ceiling, etc. is 52 in.

• Closet doors must be louvered or otherwise ventilated and

must contain a minimum of 60 sq. in. of open area equally
distributed. If the closet contains both a washer and a dryer,
doors must contain a minimum of 120 sq. in. of open area
equally distributed.