beautypg.com

Important, Notice – GE AJCQ08ACF User Manual

Page 9

background image

GEAppliances.com

When connected, the unit will be controlled

by a remote thermostat.
NOTE: The number 3 dip switch must be in

the enabled (UP) position to activate the remote

thermostat. (See the installation instructions

supplied with the remote thermostat.)

IMPORTANT:

The thermostat connections provide 24 V AC only.
If using a digital/electronic wall thermostat,

ensure it is compatible with 24 VAC signal. See

the Installation Instructions for the wall thermostat.

NOTICE:

Damage to a wall thermostat or to the electronics

can result from improper connections. Special

care must be used in connecting the wires. No line

voltage connections should be made to any circuit.

Isolate all wires in building from line voltage.

Terminal Connections Remote Thermostat - Class 2 (on some models)

The controls are located under a plastic cover

behind the front grille.

1

Remove the front grille. See the Front Grille

section of Care and Cleaning.

2

Remove the screws securing the plastic cover

over the wiring connections. Set aside screws

and plastic cover.

3

To make wiring connections, insert the wires

into the bottom of the terminals and tighten

screws securely.

4

After all desired connections have been made,

replace the plastic cover and front grille.

The owner is responsible for making all

connections and setting the appropriate dip

switches.

Terminal

connections

location

under front

grille

Fan Cycle/Continuous - Cool

When this switch is enabled (UP), it allows the indoor

fan to cycle on/off with the compressor. When this

switch is disabled (DOWN), it allows the indoor fan to run

continuously. The default setting is DOWN (continuous).

Fan Cycle/Continuous - Heat

When this switch is enabled (UP), it allows the indoor

fan to cycle on/off with the heater operation. When this

switch is disabled (DOWN), it allows the indoor fan to run

continuously. The default setting is UP (cyclic).

Class 2 - Remote Thermostat

When this switch is enabled (UP), it allows the unit

to operate with a Class 2 Remote Control Wall

Thermostat. The unit controls are disabled.

The default setting is DOWN (disabled).

Fan Cycle/Continuous - Cool

Fan Cycle/Continuous - Heat

Class 2

9

Red - 24 V AC only

Green - Low Speed Fan

Green - High Speed Fan

Yellow - Compressor

White - Heater

Common - Ground

No Function

(reserved for furture use)

No Function

(reserved for furture use)