Installation instructions, Caution, Warning – GE GTDN550GDWW User Manual
Page 3: Leak test, Reconnecting gas
Installation Instructions
3
LEAK TEST
RECONNECTING GAS
Note:7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
only on the original installation and are not to be reused
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
end of adaptor free of grease, oil and thread sealant.
CAUTION
: Use adapters as shown. Connector
nuts must not be connected directly to pipe threads.
WARNING:
1(9(586($123(1
)/$0(727(67)25*$6/($.6
FLARE
NPT
PIPE SIZE
Listed connector ANSI Z21.24 / CSA 6.10
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
AT LEAST 1/2"
3/8" NPT
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE WRENCHES.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
eck all connections for leaks with soapy solution or equivalent.
ply soap solution. Leak test solution must not contain ammonia
ch could cause damage to the brass fittings. If leaks are found,
se valve, retighten the joint, and repeat the soap test.