Installation instructions, Warning, Gas requirements – GE GTDN550GDWW User Manual
Page 2: Preparing for installation of new dryer
Installation Instructions
2
0LQLPXP&OHDUDQFH2WKHU7KDQ$OFRYHRU&ORVHW,QVWDOODWLRQ
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
GAS REQUIREMENTS
WARNING
• Installation must conform to local codes and
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/
*$6&2'($16,=
7KLV JDV GU\HU LV HTXLSSHG ZLWK D 9DOYH %XUQHU
$VVHPEO\ IRU XVH RQO\ ZLWK QDWXUDO JDV 8VLQJ
FRQYHUVLRQ NLW :(; \RXU ORFDO VHUYLFH
RUJDQL]DWLRQ FDQ FRQYHUW WKLV GU\HU IRU XVH ZLWK
SURSDQH/3JDV$//&219(56,2160867%(0$'(
BY PROPERLY TRAINED AND QUALIFIED PERSONNEL
AND IN ACCORDANCE WITH LOCAL CODES AND
25',1$1&(5(48,5(0(176
7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJ V\VWHP GXULQJ DQ\ SUHVVXUH WHVWLQJ RI WKDW
V\VWHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHP E\ FORVLQJ WKH HTXLSPHQW VKXWRȹ YDOYH
GXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJ
RIWHVWSUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
GAS SUPPLY
• A 1/8-in.National Pipe Taper thread plugged tapping,
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer. Contact your local gas utility should you have
questions on the installation of the plugged tapping.
• Supply line is to be 1/2-in. rigid pipe and equipped with
DQ DFFHVVLEOH VKXWRȺ ZLWKLQ IW RI DQG LQ WKH VDPH
room with the dryer.
8VH SLSH WKUHDG VHDOHU FRPSRXQG RU 7HÀRQ WDSH
appropriate for natural or LP gas.
listed connector ANSI Z21.24 / CSA 6.10. The length of &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\ INTERNAL DUCT CHECK THAT EXHAUST WALL TILT THE DRYER SIDEWAYS 1 PREPARING FOR INSTALLATION OF 7,3,QVWDOO\RXUGU\HUEHIRUHLQVWDOOLQJ\RXUZDVKHU DISCONNECTING GAS 5(029,1*/,17)520:$//(;+$867 OPENING • 5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQ DISCONNECT AND DISCARD OLD TURN GAS :$51,1* 1(9(55(86(2/' )/(;,%/(&211(&7256 7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNVDQG when installing gas appliances. DRYER GAS SUPPLY CONNECTION 2" 2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY NOTE: Add to vertical dimension • Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or • Installation must conform to local codes and ordinances or, in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223. $'-867,1*)25(/(9$7,21
the connect shall not exceed 3 ft.
2SHQVKXWRȺYDOYH
OPENING
HOOD DAMPER OPENS
AND CLOSES FREELY.
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
NEW DRYER
7KLVZLOODOORZEHWWHUDFFHVVZKHQLQVWDOOLQJGU\HU
H[KDXVW
GXFW
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.
SHUT-OFF VALVE
TO THE OFF
POSITION.
SHUVRQDO LQMXU\ $OZD\V XVH QHZ ÀH[LEOH FRQQHFWRUV
the distance between cabinet
bottom to floor.
below 2000 ft. elevation.
For operation at elevations above 2000 ft., input ratings
should be reduced at a rate of 4 percent for each 1000
ft. above sea level.