beautypg.com

Troubleshooting examples for msmm gui operations, Example 1, Example 2 – HP NonStop G-Series User Manual

Page 142

background image

Troubleshooting

Mid-Range Silo Media Manager Installation and User’s Guide 541530-003

C- 8

Troubleshooting Examples for MSMM GUI

Operations

Troubleshooting Examples for MSMM GUI
Operations

Example 1

PROBLEM:

Why is the MSMM GUI labeling process hanging?

SOLUTION:

Normally, this is caused by tape drives that are not defined to MSMM correctly. There
has to be a match between the way the tape drives are in the silo and the way they are
configured in MSMM.

If your tape drives in the silo are:

$TAPE1

$TAPE2

$TAPE3

If you have MSMM configured as:

$TAPE2

$TAPE1

$TAPE3

Then labeling will not work and it will hang. The way to get out of this, if you are not
sure how they are plugged in, is to drag a tape to the top tape drive, wait and see what
tape drive the system sees the tape on, write that name down and continue on with all
the tape drives. Next, re-configure MSMM with the tape drives in the correct order the
way the system saw them.

Example 2

PROBLEM:

Labeling is not working, the queue just sits there and nothing happens...

SOLUTION:

Labeling with the MSMM GUI will only work on a system with tape drives attached to it.
Whatever system the MSMM GUI is attached to has to have a tape drive in the silo. To
configure a Client MSMM for your system, refer to Sections 2 and 3 in this manual.