GAS LINE SIZE

Natural Gas

Nominal Iron Pipe Size*

1/2"

3/4"

1"

MAXIMUM LENGTH

10'

40'

150'

Liquid Propane

Semi-rigid Tubing

1/2"

5/8"

3/4"

7/8"

MAXIMUM LENGTH

NOT

RECOMMENDED

20'

60'

150'

* Flex tubing greatly reduces capacity and, therefore, is not recommended.

Minimum Vent Size* and Height

Minimum Diameter

Minimum Height**

5 inches

6 feet**

* NOTE: Vent size must not be restricted. Installation must comply with national fuel gas code venting requirements

for a 117,000 Btu Category I appliance and any applicable local codes.

Water Pressure

For installation on well systems, insure that your water pressure is between 30 - 50 psi.

** NOTE: Minimum vent height must be 6 feet, provided there are no elbows. Termination of the vent must be 2

feet above any obstruction within a 10 foot radius of vent pipe. Consult your gas utility or National Fuel Gas Code

if vent will have elbows or share venting with another appliance. The vent connector should have as much vertical

rise as possible (minimum 12") before any horizontal run.

INSTALLATION CHECKLIST