beautypg.com

KAL EQUIP KAL 3840 User Manual

Page 63

background image

Trigger

Trigger Source

: CH A, CH B, TRIGGER (External trigger)

Sensitivity (CH A)

: < 1.0 div to 5 MHz

Sensitivity (Trigger)

: 0.2 V p-p

Modes

: Single shot, Normal, Auto

Coupling

: AC, DC

Slope

: Rising and falling edge

Others

Glitch Snare

: SCOPE Mode (Component test only)

Acquire Mode

: SCOPE Mode

Setup memory

: 8 Waveform & Setup

Reference waveform

: 51 Waveform and Setup

Cursor

: Time and Volt

Instrument Setup

: Language, Contrast, Graticule

Graphing Multimeter (GMM) Specifications

DC Voltage Measurement

> Input Impedance : 10 M

AC Voltage Measurement

> Input Impedance : 10 M

8-3

Back Probe Pins

: 3 ea (red, yellow and black)

2 mm Adaptor

: 3 ea (red, yellow and black)

Secondary Pick-up

: 1 ea

Ground Lead

for Capacitive Secondary Probe

: 1 ea (black)

Inductive Pick-up

: 1 ea

Soft Carrying Case

: 1 ea

USB Interface

Cable and Software (Optional) : 1 ea

Current Probe - CA113 OS/AT (Optional) : 1 ea

Diesel Probe Set (Optional)

: 1 ea

Temperature Probe (Optional)

: 1 ea

Isolated 12V Charging Adaptor (Optional) : 1 ea

Isolated 24V Charging Adaptor (Optional) : 1 ea

Scope Specifications

Horizontal

Sample rate

: 25 Mega sample/second

Record length

: 1000 Points

Update rate

: Real time, Roll

Accuracy

: ± (0.1 % + 1 pixel)

Sweep rate

: 1 µs to 50 sec in a 1, 2, 5 sequence (Scope mode)

5 s to 24 Hours in a 1, 2, 5 sequence (GMM mode)

Vertical

Band width

: DC to 5 MHz ; -3 dB

Resolution

: 8 bit

Channel

: 2 Channel

Coupling

: AC, DC, GND

Input Impedance

: 1 Mohm / 70 pF

Maximum Input Voltage

: 300 V

Volt/Division

: 50 mV to 100 V in a 1, 2, 5 sequence

Accuracy

: ± 3 %

8-2

Range

500 mV

5 V

50 V

500 V

600 V

Resolution

0.1 mV

0.001 V

0.01 V

0.1 V

1 V

Accuracy

± (0.3 % + 5 d)

Range

500 mV

5 V

50 V

500 V

600 V

Resolution

0.1 mV

0.001 V

0.01 V

0.1 V

1 V

40 Hz ~ 400 Hz

± (0.5 % + 5 d)

400 Hz ~ 20 kHz

± (2.5 % + 5 d)

Accuracy